Post hoc analysis of a randomised controlled trialBenefit found
How do DDLS and cup:disc ratio compare for staging severe glaucoma?
Who
382
Participants aged 18 years or older with open-angle glaucoma · Eye Department of Kilimanjaro Christian Medical Centre, Tanzania
Compared
Disc Damage Likelihood Scale: AROC 0.90 (95% CI 0.87 to 0.93)
Vertical cup:disc ratio: AROC 0.88 (95% CI 0.85 to 0.91)
Main outcome
Identification of severe or end-stage glaucoma
Result: Spearman's rank correlation 0.73 for DDLS and 0.71 for vCDR
Bottom line: Both structural staging systems differentiate severe glaucoma, with the Disc Damage Likelihood Scale showing a moderate advantage over cup:disc ratio.
Clinical question: How do DDLS and cup:disc ratio compare for staging severe glaucoma?
Why it matters: It is unknown how well structural staging systems can differentiate stages of functional vision loss in patients with severe or end-stage glaucoma.
Key points
Researchers analyzed 382 eyes from 201 participants with open-angle glaucoma to compare two methods of staging disease severity.
The Disc Damage Likelihood Scale had an area under the receiver operating characteristic curve of 0.90, while the vertical cup to disc ratio was 0.88.
Advanced structural stages, vision impairment, higher intraocular pressure, and fewer financial resources were associated with functional severe or end-stage glaucoma.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Background
Glaucoma staging is critical for treatment planning but has rarely been tested in severe/end-stage disease. We compared the performance of the Disc Damage Likelihood Scale (DDLS) and cup:disc ratio (CDR) using a functional glaucoma staging system (GSS) as the reference standard. Methods
Post hoc analysis of a randomised controlled trial at the Eye Department of Kilimanjaro Christian Medical Centre, Tanzania. Eligible participants (aged ≥18 years) with open-angle glaucoma, intraocular pressure (IOP) of >21 mm Hg, were randomised to timolol 0.5% eye drops or selective laser trabeculoplasty. Fundoscopy established vertical and horizontal CDRs and DDLS. Visual acuity and static visual fields were graded (GSS). The study used area under the receiver operating characteristic (AROC) curves and Spearman's rank correlation coefficients to compare staging systems. Logistic regression with generalised estimating equations determined risk factors of functional severe/end-stage glaucoma. Results
382 eyes (201 participants) were evaluated; 195 (51%) had severe or end-stage glaucoma; mean IOP was 26.7 (SD 6.9) mm Hg. DDLS yielded an AROC of 0.90 (95% CI 0.87 to 0.93), vertical cup:disc ratio (vCDR) of 0.88 (95% CI 0.85 to 0.91, p=0.048) for identifying severe/end-stage disease. Correlation coefficients comparing GSS to DDLS and vCDRs were 0.73 and 0.71, respectively. Advanced structural stages, vision impairment, higher IOP and less financial resources were risk factors of functional severe/end-stage glaucoma. Conclusion
This study indicates that both structural staging systems can differentiate severe/end-stage glaucoma from less severe disease, with a moderate advantage of DDLS over CDR. Clinical examination of the optic disc plays an important role in addition to functional assessment when managing severe/end-stage glaucoma.
Abstract reproduced under the article’s CC BY licence.
Philippin H, Matayan EN, Knoll KM, Macha E, Mbishi S, Makupa A. Differentiating stages of functional vision loss from glaucoma using the Disc Damage Likelihood Scale and cup:disc ratio. Br J Ophthalmol. 2024. doi:10.1136/bjo-2022-321643