Dynamic Changes in High-Sensitivity Cardiac Troponin I Levels Associate With Variations in Cardiovascular Risk Scores in the General Population
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
In the general population, elevated hs-cTnI (high-sensitivity cardiac troponin I) levels are linked to adverse cardiovascular outcomes. Whether changes in hs-cTnI within the normal range are associated with variations in cardiovascular risk scores remains unclear. Methods
This observational substudy of the CV-PREVITAL (Strategies for Primary Cardiovascular Prevention in the Italian Population) project evaluated 810 subjects (522 women) in primary prevention. Hs-cTnI was measured at baseline and after 12 months in 473 participants. Cardiovascular risk was assessed using validated scores along with diet adherence and sleep quality. Clinical and laboratory parameters were recorded. Participants received structured lifestyle counseling. Results
At baseline, hs-cTnI was undetectable in 59% of participants. Detectable hs-cTnI was associated with older age (58 versus 55 years), higher body mass index (26 versus 24 kg/m2), greater waist circumference (91 versus 85 cm), higher blood pressure (129 versus 123 mm Hg), lower high-density lipoprotein cholesterol (56 versus 59 mg/dL), higher glycated hemoglobin (40 versus 38 mmol/mol), all PConclusions
In this primary-prevention cohort, the presence of detectable hs-cTnI was associated with a less favorable risk profile. However, its usefulness in the longitudinal monitoring of cardiovascular risk changes requires validation against cardiovascular outcomes.
Topics
Spotted a mistake? Suggest a correction