Early Functional Outcomes After Evolutionary Total Knee Arthroplasty: A Randomized Controlled Trial. Is New Always Better?
Key result: Newer knee implant design showed no difference in early functional outcomes compared to older design
Single-blinded, noninferiority, randomized controlled trialNo clear difference
Are early functional outcomes different between evolutionary and traditional total knee replacement designs?
Who
150
Patients undergoing total knee replacement
Compared
ATTUNE implant
P.F.C. SIGMA implant
Main outcome
Clinical and functional outcome measures
Bottom line: The ATTUNE implant showed no inferiority compared to the P.F.C. SIGMA implant in early functional outcomes.
Limitation: Further work should assess the effect of non-implant-related factors on patient outcomes.
JBJS Open Access · 2021-07-28 · Save PNG
Key points
- Researchers compared 150 patients receiving either the ATTUNE or the P.F.C. SIGMA total knee replacement systems.
- No differences were observed between the two implant groups in any clinical or functional outcome measures at any time point.
- Tourniquet time, the duration a pressure cuff is used to limit blood flow during surgery, was shorter in the P.F.C. SIGMA group (p = 0.001).
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: Panchani SK, Divecha HM, Lafferty R, et al. Early Functional Outcomes After Evolutionary Total Knee Arthroplasty: A Randomized Controlled Trial. Is New Always Better?. JBJS Open Access. 2021. doi:10.2106/JBJS.OA.21.00016