Visual abstractsVisuals
ResearchAnnals of Intensive Care · Jul 25, 2026

Early red blood cell transfusion burden, hemoglobin at first transfusion, and in-hospital mortality in patients supported with veno-arterial ECMO: a multicenter cohort study

Ju MH, Ju S, Jeong IS, Kim HS, Cho YH, Jung JS, et al
Critical CareAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Red blood cell (RBC) transfusion is common during venoarterial extracorporeal membrane oxygenation (VA-ECMO), but the prognostic relevance of early cumulative transfusion burden and hemoglobin (Hb) at transfusion initiation remains uncertain. We examined associations of ECMO day-1 RBC dose and, among transfused patients, first-transfusion Hb and transfusion-pattern phenotype with in-hospital mortality. Methods Adults aged ≥18 years initiating peripheral VA-ECMO at six Korean centers between January 2018 and March 2025 were analyzed. The primary analysis used a 24 -h landmark cohort of patients alive and still receiving ECMO beyond 24 h. Day-1 RBC dose was categorized as 0, 1-2, 3-4, or ≥5 units and modeled per 2-unit increase. Adjusted risk ratios (RRs) were estimated using modified Poisson regression. Secondary analyses assessed first-transfusion Hb and consistent- versus variable threshold phenotypes among transfused complete cases. Results Among 2,020 included patients, 1,708 entered the 24-h landmark cohort, and 1,140 complete cases comprised the adjusted primary analysis. Compared with no day-1 transfusion, adjusted RRs for in-hospital mortality were 1.20 (95% confidence interval [CI], 1.02-1.40) for 1-2 units, 1.37 (95% CI, 1.17-1.59) for 3-4 units, and 1.48 (95% CI, 1.28-1.71) for ≥5 units. Each 2-unit increase was associated with higher mortality (adjusted RR, 1.08; 95% CI, 1.05-1.11), with concordant findings over ECMO days 1-2 (adjusted RR, 1.06; 95% CI, 1.04-1.08). Among 1,043 transfused complete cases with qualifying pretransfusion Hb, each 1 g/dL decrease in first-transfusion Hb was associated with higher mortality (adjusted RR, 1.15; 95% CI, 1.10-1.20). The association was evident in the consistent-threshold phenotype (adjusted RR, 1.16; 95% CI, 1.10-1.22) but not in the variable-threshold phenotype (adjusted RR, 1.02; 95% CI, 0.92-1.12). Conclusions In adults receiving peripheral VA-ECMO, early RBC transfusion burden showed a graded association with in-hospital mortality, whereas lower first-transfusion Hb was a prognostic marker chiefly within the consistent-threshold phenotype. These findings support dose- and threshold-aware prognostic assessment but do not establish causality or define an optimal transfusion threshold.

DOI: 10.1016/j.aicoj.2026.100125 · PubMed: 42571564

Spotted a mistake? Suggest a correction

More in Critical Care

Meta-analysisCrit Care · Nov 19, 2026 · Critical Care

Corticosteroids in sepsis have conflicting mortality conclusions in reviews

Discordant evidence on corticosteroids in sepsis: a meta-research study

ResearchPediatricResuscitation · Nov 17, 2026 · Critical Care

Eighty-nine percent of infants survived 28 days after chest compressions at birth in 2024

Survival after neonatal chest compressions at birth: Temporal trends and prognostic factors in a population-based cohort, Queensland, Australia

ResearchResuscitation · Nov 17, 2026 · Critical Care

Bystanders attaching AEDs had highest 30-day survival rate of 28 percent

Survival after out of hospital cardiac arrest in relation to AED usage in a multi response system including AED equipped drones

ResearchResuscitation · Nov 17, 2026 · Critical Care

Foreign body airway obstruction caused 1.1% of out-of-hospital cardiac arrests

Out-of-hospital cardiac arrests due to foreign body airway obstruction: A CanROC registry, retrospective cohort study

ResearchResuscitation · Nov 17, 2026 · Critical Care

Commercially available multimodal LLMs for EEG-based prognostication after cardiac arrest