Visual abstractsVisuals
ResearchRespiratory Research · May 12, 2026

Effect of airway constriction on ventilation inhomogeneity: multiple-breath washout indices and intrapulmonary reverse flow

Kim M, Yoon S, Petralia LS, Doganay O, Yamakawa M, Brightling C, et al
PulmonologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Small airway dysfunction is an early and clinically important feature of many respiratory diseases but remains difficult to detect using conventional physiological tests. Multiple-breath washout (MBW) is widely used to assess ventilation heterogeneity; however, its sensitivity to the specific location and severity of airway narrowing is not fully understood. Methods Nitrogen MBW was simulated using a physiologically realistic computational airway model reconstructed from high-resolution chest CT imaging. Sixty-four airway constriction scenarios were examined, varying systematically by airway generation, constriction ratio, and constricted branch ratio. Standard MBW indices (LCI, Sacin, and Scond) were evaluated alongside a novel intrapulmonary reverse flow (RF) metric. Sensitivity to airway structural changes was assessed using Spearman's rank correlation and multiple linear regression analyses. Results MBW indices were predominantly sensitive to severe proximal constriction (Gen 5-9, ≥ 75% severity) with minimal changes observed in distal scenarios. RF showed strong correlations with all MBW indices, particularly Sacin (ρ = 0.93, p < 0.0001), and consistently increased with constriction at any given airway location. Notably, while Sacin has long been regarded as a marker of peripheral convective-diffusive heterogeneity at the acinar level, our findings demonstrate that convective heterogeneities arising from more proximal airway constrictions generate significant RF, which in turn influences the Sacin signal. In multivariable regression, RF emerged as the most sensitive marker of ventilation heterogeneity arising from airway structural alterations, explaining the greatest proportion of variance (Adj. R2 = 0.933, p < 0.001), exceeding that of Sacin (0.826), LCI (0.732), and Scond (0.564). Conclusions In simulations, RF was sensitive to ventilation abnormalities arising from mild and distal airway narrowing. As a physiologically interpretable, flow-based marker, RF offers a novel and complementary means of enhancing the sensitivity of MBW for the early detection and motivates further experimental and clinical validation. Importantly, by identifying RF as a convective link between central airway narrowing and peripheral washout behaviour, our study suggests that Sacin reflects a broader spectrum of ventilation disturbances than previously assumed, providing a new mechanistic basis for interpreting MBW indices.

Topics

Humans; Pulmonary Ventilation; Lung; Computer Simulation; Models, Biological

DOI: 10.1186/s12931-026-03695-2 · PubMed: 42116140

Spotted a mistake? Suggest a correction

More in Pulmonology

Eur Respir J · Nov 23, 2026 · Review · Pulmonology

BMP-9 and BMP-10 regulate pulmonary vascular resilience through complex pathways

Eur Respir J · Nov 23, 2026 · Randomized trial · Pulmonology Visual abstract

Needle aspiration reduced hospital stay by nearly five days for pneumothorax patients

Eur Respir J · Nov 23, 2026 · Randomized trial · Pulmonology Visual abstract

Inhaled itraconazole improved lung function and asthma control at 40mg dose

Chest · Nov 21, 2026 · Research · Pulmonology

Association between exertional dyspnea and insomnia in a population-based cohort

Chest · Nov 21, 2026 · Research · Pulmonology

Combination therapy reduces obstructive sleep apnea severity by roughly half