Visual abstractsVisuals
ResearchAmerican Journal of Ophthalmology · Nov 28, 2025

Effect of Angle Kappa on the Refractive Prediction Accuracy in Cataract Patients After Myopic LASIK/PRK

Yuan H, Zhang J, Zheng Y, Lin H, Xie X, Hu X, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Purpose To evaluate the impact of angle kappa on prediction accuracy in patients after myopic laser-assisted in-situ keratomileusis (LASIK)/photorefractive keratectomy (PRK). Design Retrospective, consecutive interventional case-series study. Methods This study included 127 postmyopic-LASIK/PRK cataract patients (176 eyes). Three different keratometry (K) values measured by 2 devices were assessed, including simulated keratometry (SimK) obtained by IOLMaster 700 at 2.5 mm ring centered on corneal vertex and SimK derived from Pentacam AXL in 3 mm zone centered on corneal vertex (Pentacam [CV]) and pupil center (Pentacam [PC]). The performance of the Barrett True-K formula based on vertex-centered K values (IOLMaster 700; Pentacam [CV]) and pupil-centered K values (Pentacam [PC]) was compared. Subgroup analysis was performed using angle kappa (<0.4 mm; ≥0.4 mm). Result The hyperopic prediction error (PE) of the IOLMaster 700 and Pentacam (CV) modes increased with larger angle kappa. Both in total and in eyes with angle kappa <0.4 mm, compared with other modes, the IOLMaster 700 mode showed no systematic bias and relatively lower absolute PE. For eyes with angle kappa ≥0.4 mm, IOLMaster 700 and Pentacam (CV) modes demonstrated hyperopic PE (0.43-0.46 D, P < .05), while the Pentacam (PC) mode displayed no systematic bias, relatively lower mean absolute PE (0.70 D vs 0.90-0.96 D) and the highest percentage of eyes with PE within ±0.5 D (51.22% vs 36.59%-41.46%). Conclusion In postmyopic-LASIK/PRK patients, the prediction accuracy decreased with greater angle kappa when using the corneal vertex-centered K values. The pupil-centered K values were preferred for these patients with angle kappa ≥0.4 mm.

Topics

Predictive Value of Tests; Retrospective Studies; Humans; Male; Female; Adult; Middle Aged; Cataract; Cataract Extraction; Keratomileusis, Laser In Situ; Cornea; Corneal Topography

DOI: 10.1016/j.ajo.2025.11.042 · PubMed: 41319828

Cite this article

Yuan H, Zhang J, Zheng Y, Lin H, Xie X, Hu X. Effect of Angle Kappa on the Refractive Prediction Accuracy in Cataract Patients After Myopic LASIK/PRK. Am J Ophthalmol. 2025. doi:10.1016/j.ajo.2025.11.042

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Invest Ophthalmol Vis Sci · Sep 9, 2026 · Review · Ophthalmology

A Systems View of Posterior Capsule Opacification: TGF-β/ROS Signaling, Mitochondrial Homeostasis, and Injury/Aging Cues-Therapeutic Opportunities

Br J Ophthalmol · Sep 22, 2026 · Research · Pediatric · Ophthalmology

Exponential myopic shift over 13 years in aphakic and pseudophakic eyes after congenital cataract surgery within 6 months of birth

Invest Ophthalmol Vis Sci · May 4, 2026 · Research · Pediatric · Ophthalmology

Longitudinal Changes in Nystagmus Following Late Treatment for Congenital Blindness

J Gerontol A · Jan 20, 2026 · Research · Geriatrics, Ophthalmology

The association of cataract surgery with risk of falls and fractures among Medicare enrollees with cataract

Lancet Healthy Longev · Feb 10, 2026 · Research · Geriatrics, Ophthalmology

Prevalence of death in people with vision impairment from cataracts before treatment: a case study from Kenya