Effect of Angle Kappa on the Refractive Prediction Accuracy in Cataract Patients After Myopic LASIK/PRK
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Purpose
To evaluate the impact of angle kappa on prediction accuracy in patients after myopic laser-assisted in-situ keratomileusis (LASIK)/photorefractive keratectomy (PRK). Design
Retrospective, consecutive interventional case-series study. Methods
This study included 127 postmyopic-LASIK/PRK cataract patients (176 eyes). Three different keratometry (K) values measured by 2 devices were assessed, including simulated keratometry (SimK) obtained by IOLMaster 700 at 2.5 mm ring centered on corneal vertex and SimK derived from Pentacam AXL in 3 mm zone centered on corneal vertex (Pentacam [CV]) and pupil center (Pentacam [PC]). The performance of the Barrett True-K formula based on vertex-centered K values (IOLMaster 700; Pentacam [CV]) and pupil-centered K values (Pentacam [PC]) was compared. Subgroup analysis was performed using angle kappa (<0.4 mm; ≥0.4 mm). Result
The hyperopic prediction error (PE) of the IOLMaster 700 and Pentacam (CV) modes increased with larger angle kappa. Both in total and in eyes with angle kappa <0.4 mm, compared with other modes, the IOLMaster 700 mode showed no systematic bias and relatively lower absolute PE. For eyes with angle kappa ≥0.4 mm, IOLMaster 700 and Pentacam (CV) modes demonstrated hyperopic PE (0.43-0.46 D, P < .05), while the Pentacam (PC) mode displayed no systematic bias, relatively lower mean absolute PE (0.70 D vs 0.90-0.96 D) and the highest percentage of eyes with PE within ±0.5 D (51.22% vs 36.59%-41.46%). Conclusion
In postmyopic-LASIK/PRK patients, the prediction accuracy decreased with greater angle kappa when using the corneal vertex-centered K values. The pupil-centered K values were preferred for these patients with angle kappa ≥0.4 mm.
Topics
Cite this article
Yuan H, Zhang J, Zheng Y, Lin H, Xie X, Hu X. Effect of Angle Kappa on the Refractive Prediction Accuracy in Cataract Patients After Myopic LASIK/PRK. Am J Ophthalmol. 2025. doi:10.1016/j.ajo.2025.11.042
Spotted a mistake? Suggest a correction