Effect of Ceiling Fans on Core Temperature in Bed-Resting Older Adults Exposed to Indoor Overheating
Key result: Ceiling fans reduced core temperature and cardiovascular strain in older adults during indoor overheating
Key points
- Twenty bed-resting participants with a median age of 71 years were studied under simulated indoor overheating of 31°C and 45% relative humidity.
- Using a ceiling fan at ~1.5 m/s was associated with a peak core temperature of 37.6 [0.2]°C compared to 37.8 [0.2]°C in the control group.
- The use of a ceiling fan was associated with significant reductions in heart rate, fluid consumption, and thermal discomfort, though it did not completely stop physiological strain.
Why it matters: The efficacy of ceiling fans in very warm indoor temperatures of approximately 31°C remains understudied for vulnerable populations like older adults.
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: O'Connor FK, Meade RD, Janetos KT, et al. Effect of Ceiling Fans on Core Temperature in Bed-Resting Older Adults Exposed to Indoor Overheating. J Am Geriatr Soc. 2026;74(1):200-204. doi:10.1111/jgs.70109
Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/effect-of-ceiling-fans-on-core-temperature-in-bed-resting-older-1cg76vi/ (AI-assisted from the abstract; check the paper before relying on it).