Collagen scaffold was more effective than intrauterine devices at preventing uterine scar recurrence
Effect of collagen scaffold vs. intrauterine device on preventing recurrence of intrauterine adhesions: a multicenter randomized controlled trial
Clinical question: Does collagen scaffold prevent intrauterine adhesion recurrence better than an intrauterine device?
Why it matters: Clinicians need to determine whether a collagen scaffold or an intrauterine device is more effective at preventing the recurrence of uterine scar tissue after surgery.
- Researchers studied 195 patients aged 20-40 with moderate intrauterine adhesions, which are scar tissue inside the uterus, comparing a collagen scaffold to an intrauterine device.
- The rate of no adhesion recurrence at a two-month follow-up was 78.6% in the collagen scaffold group compared to 58.8% in the intrauterine device group.
- There was no significant difference between the two groups regarding the American Fertility Society score or the decrease in that score at the two-month follow-up.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Wang H, Gu X, Li T, et al. Effect of collagen scaffold vs. intrauterine device on preventing recurrence of intrauterine adhesions: a multicenter randomized controlled trial. Fertil Steril. 2026;125(4):708-716. doi:10.1016/j.fertnstert.2025.08.035
Spotted a mistake? Suggest a correction