Randomized trialClinical Infectious Diseases · Aug 23, 2021

Effectiveness of Continuous Endotracheal Cuff Pressure Control for the Prevention of Ventilator-Associated Respiratory Infections: An Open-Label Randomized, Controlled Trial

Dat VQ, Minh Yen L, Thi Loan H, Dinh Phu V, Thien Binh N, Geskus RB, et al
Infectious DiseasePulmonologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Background An endotracheal tube cuff pressure between 20 and 30 cmH2O is recommended to prevent ventilator-associated respiratory infection (VARI). We aimed to evaluate whether continuous cuff pressure control (CPC) was associated with reduced VARI incidence compared with intermittent CPC. Methods We conducted a multicenter open-label randomized controlled trial in intensive care unit (ICU) patients within 24 hours of intubation in Vietnam. Patients were randomly assigned 1:1 to receive either continuous CPC using an automated electronic device or intermittent CPC using a manually hand-held manometer. The primary endpoint was the occurrence of VARI, evaluated by an independent reviewer blinded to the CPC allocation. Results We randomized 600 patients; 597 received the intervention or control and were included in the intention to treat analysis. Compared with intermittent CPC, continuous CPC did not reduce the proportion of patients with at least one episode of VARI (74/296 [25%] vs 69/301 [23%]; odds ratio [OR] 1.13; 95% confidence interval [CI] .77-1.67]. There were no significant differences between continuous and intermittent CPC concerning the proportion of microbiologically confirmed VARI (OR 1.40; 95% CI .94-2.10), the proportion of intubated days without antimicrobials (relative proportion [RP] 0.99; 95% CI .87-1.12), rate of ICU discharge (cause-specific hazard ratio [HR] 0.95; 95% CI .78-1.16), cost of ICU stay (difference in transformed mean [DTM] 0.02; 95% CI -.05 to .08], cost of ICU antimicrobials (DTM 0.02; 95% CI -.25 to .28), cost of hospital stay (DTM 0.02; 95% CI -.04 to .08), and ICU mortality risk (OR 0.96; 95% CI .67-1.38). Conclusions Maintaining CPC through an automated electronic device did not reduce VARI incidence. Clinical trial registration NCT02966392.

Topics

Humans; Intubation, Intratracheal; Length of Stay; Pneumonia, Ventilator-Associated; Respiratory Tract Infections; Ventilators, Mechanical

DOI: 10.1093/cid/ciab724 · PubMed: 34420048 · Registered: NCT02966392

Cite this article

Dat VQ, Minh Yen L, Thi Loan H, Dinh Phu V, Thien Binh N, Geskus RB. Effectiveness of Continuous Endotracheal Cuff Pressure Control for the Prevention of Ventilator-Associated Respiratory Infections: An Open-Label Randomized, Controlled Trial. Clin Infect Dis. 2021. doi:10.1093/cid/ciab724

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

Similar articles

Randomized trial · Crit Care · Dec 1, 2022 · Critical Care, Pulmonology

Ceftolozane/tazobactam was associated with lower 28-day mortality than meropenem in patients failing initial pneumonia therapy

Randomized trial · Intensive Care Med · Jun 2, 2026 · Critical Care, Pulmonology

Automatic cuff pressure management and secretion drainage did not reduce bacterial tracheal colonization

Meta-analysis · Crit Care · Sep 17, 2024 · Critical Care, Pulmonology

Metal-coated breathing tubes were associated with lower rates of ventilator-associated pneumonia in patients

Randomized trial · Respir Res · Aug 1, 2026 · Pulmonology, Critical Care

Specialized endotracheal tube prevented microbial communities from becoming more similar during mechanical ventilation

Meta-analysis · Br J Anaesth · Sep 24, 2022 · Anesthesiology, Critical Care

Bayesian analysis of a systematic review of early versus late tracheostomy in ICU patients