Visual abstractsVisuals
ResearchThe Laryngoscope · Apr 28, 2026

Electrode Contacts in the Functional Hearing Region for Pediatric Cochlear Implant Recipients

Quinonez Del Cid E, Dillon MT, Park LR, Brown KD, Thompson NJ
ENT (Otolaryngology)Pediatric

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objectives Examine the incidence of one or more electrode contacts placed within the region of functional acoustic hearing and the potential influence of electrode positioning on speech recognition for pediatric cochlear implant (CI) recipients. Methods A retrospective review for pediatric CI recipients of straight electrode arrays with preserved low-frequency hearing (an unaided threshold of ≤ 80 dB HL at 250 Hz) was conducted at a tertiary referral center. Intraoperative X-rays were used to determine the angular insertion depth (AID) of each electrode. Proximity of contacts to the functional acoustic hearing region was calculated using AID and postoperative unaided thresholds. For electric-acoustic stimulation (EAS) users, the association between proximity values and CNC word recognition in quiet was reviewed at 3-, 6-, and 12-months post-activation. Results Among 69 ears, 90% had at least one electrode contact within the functional acoustic hearing region. Proximity values ranged from -131° to 450° (mean: 100°, SD: 120°). For EAS users with speech recognition data (n = 29), proximity values were not significantly associated with post-activation CNC scores (p ≥ 0.212). Conclusions Most pediatric CI recipients with hearing preservation had at least one electrode contact in the region of functional acoustic hearing. Proximity was not significantly associated with word recognition in quiet for EAS users, though this subgroup was limited in sample size. Further studies in pediatric EAS users are needed to understand the potential relationship with speech recognition in noise and to determine the benefits of individualizing array selection and/or EAS mapping.

Topics

Humans; Cochlear Implants; Retrospective Studies; Female; Child, Preschool; Cochlear Implantation; Speech Perception; Child; Male; Infant; Auditory Acuity; Hearing

DOI: 10.1002/lary.70594 · PubMed: 42049500

Spotted a mistake? Suggest a correction

More in ENT (Otolaryngology)

Meta-analysisVisual abstracteClinicalMedicine · Oct 26, 2026 · Oncology, ENT (Otolaryngology)

Weekly cisplatin and platinum-based chemoradiotherapy improve overall survival in head and neck cancer

Radiosensitising strategies in locally advanced head and neck cancer: a systematic review and network meta-analysis of randomised controlled trials (RADIANCE-NMA)

ResearchInt Forum Allergy Rhinol · Oct 18, 2026 · ENT (Otolaryngology)

Immune cell changes after sinus surgery differ between two conditions

Changes in Peripheral Immune Cell Subsets Following Endoscopic Sinus Surgery Differ Between CRSwNP and AERD

ResearchJAMA Otolaryngol · Oct 15, 2026 · ENT (Otolaryngology)

Mandated hearing aid coverage rose to 52.5% for US youth and 19.2% for adults

Longitudinal Growth of Mandated Hearing Aid Benefits in the US

ResearchJAMA Otolaryngol · Oct 8, 2026 · ENT (Otolaryngology)

Precision phenotyping identified genetic variants for sensorineural hearing loss better than diagnostic codes

Precision Phenotyping With Audiometric Data and Gene Discovery for Sensorineural Hearing Loss

ResearchOtolaryngol Head Neck Surg · Oct 6, 2026 · ENT (Otolaryngology)

Primary Tumor Location and Lymphatic Spread in Papillary Thyroid Carcinoma