Novel devices reduced radiation exposure in cardiac catheterization laboratory
Evaluating Standard Shielding Versus Novel Enhanced Radiation Protection Devices in the Cardiac Catheterization Laboratory
Why it matters: Laboratory members have occupational risks from scatter radiation
- 135 patients were studied with 3 shielding conditions compared.
- Annualized effective dose equivalent was 51.4, 7.0, and 2.4 mRem for groups 1, 2, and 3.
- ERPDs significantly lowered scatter radiation exposure to laboratory members.