Visual abstractsVisuals
ResearchClinical Infectious Diseases · Jan 21, 2026

Evaluating the Cepheid Xpert TB/LTBI Research-Use-Only Assay for Detection of Active and Latent Mycobacterium tuberculosis Infection

Sweetser B, Nguyen H, Dang H, Katumba D, Mochizuki T, Wang Q, et al
Infectious DiseaseAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Accurate nonsputum tests are essential for improving tuberculosis (TB) detection. We report the first evaluation of the Xpert TB/LTBI assay (research-use-only; Cepheid, USA), which detects 9 Mycobacterium tuberculosis antigen-stimulated mRNA targets from blood. Methods We enrolled individuals ≥12 years with presumptive TB from clinics in Uganda and Vietnam. All participants underwent sputum- (liquid culture; Xpert MTB/RIF Ultra) and blood-based (Xpert TB/LTBI; QuantiFERON-TB Gold Plus [QFT-Plus]) testing. Participants were classified as having active TB (positive sputum results), latent TB infection (LTBI; positive QFT-Plus with negative sputum results), or no TB infection. Diagnostic accuracy for active TB (primary analysis) and of a 2-step algorithm that first predicted TB infection (active TB or LTBI) and then distinguished active TB from LTBI was assessed using logistic regression and receiver operating characteristic analysis. Results Among 214 participants included, 56.5% were male, 9.3% were with HIV, 29.0% had active TB, and 31.8% had LTBI. Xpert TB/LTBI area under the curve (AUC) was 0.92 (95% CI: .88-.96) for identifying active TB, and sensitivity was 93.5% (95% CI: 84.6-97.5) and specificity 76.3% (95% CI: 69.0-82.4) at a cut-point that achieved ≥90% sensitivity. In the 2-step algorithm, Xpert TB/LTBI had high accuracy for identifying TB infection in the first step, but accuracy was lower for distinguishing active TB from LTBI in the second step. Conclusions Xpert TB/LTBI exceeded World Health Organization (WHO)-recommended minimum accuracy targets for a TB screening test. However, further refinement is needed to improve its ability to distinguish active TB from LTBI.

Topics

Uganda; Vietnam; Mycobacterium tuberculosis; Tuberculosis; Sputum; Latent Tuberculosis; Diagnosis, Differential; Area Under Curve; Sensitivity and Specificity; Algorithms; Humans; Male

DOI: 10.1093/cid/ciag005 · PubMed: 41562455

Cite this article

Sweetser B, Nguyen H, Dang H, Katumba D, Mochizuki T, Wang Q. Evaluating the Cepheid Xpert TB/LTBI Research-Use-Only Assay for Detection of Active and Latent Mycobacterium tuberculosis Infection. Clin Infect Dis. 2026. doi:10.1093/cid/ciag005

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Lancet Glob Health · Sep 24, 2026 · Research · Public & Global Health

Pooled testing for tuberculosis had slightly lower sensitivity than individual testing

Clin Microbiol Infect · May 29, 2026 · Research · Infectious Disease

Diagnostic accuracy and potential resource savings of pooled sputum testing with Xpert MTB/RIF Ultra for tuberculosis among adults in Vietnam: a cross-sectional study

Clin Infect Dis · Mar 20, 2026 · Research · Infectious Disease

Prevalence and Predictors of Tuberculosis in Adults and Adolescents With Sputum Trace Ultra Results in 2 High-Burden Clinical Settings

Clin Infect Dis · Mar 10, 2026 · Research · Infectious Disease

Diagnostic Yield of Tongue Swab- Compared to Sputum-Based Molecular Testing for Tuberculosis in Four High-Burden Countries

Lancet Microbe · Dec 22, 2025 · Review · Infectious Disease

The need for interconnected global biorepositories from tuberculosis studies to address fundamental questions at scale