Evaluating the potential of quantitative assessment of intraoperative fasciocutaneous flap perfusion using microscope-integrated indocyanine green fluorescence angiography
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Perfusion-related complications are a leading cause of morbidity and flap loss in reconstructive surgery. While indocyanine green fluorescence angiography (ICG-FA) is commonly used, its subjective interpretation may miss early signs of perfusion disturbances. Quantitative ICG-FA (Q-ICG-FA) offers a more objective method, but its potential in fasciocutaneous flaps remains insufficiently studied. Methods
This retrospective study analyzed intraoperative ICG-FA data from patients undergoing fasciocutaneous flap reconstruction. Fluorescence-time curves (FTCs) were generated from three regions of interest (ROIs): reference tissue (ROI1), proximal flap (ROI2), and distal flap (ROI3). FTCs and derived quantitative parameters, including time-to-peak (Ttp) and normalized inflow/outflow slopes, were compared between patients with (PRC) and without (No PRC) perfusion-related complications. Results
Twenty patients were included. Seven patients experienced a perfusion-related complication, most commonly venous congestion (n = 5). FTCs of compromised flaps showed delayed fluorescence peaks and reduced washout, most pronounced in ROI3. Quantitatively, the PRC group showed prolonged Ttp in ROI2 (105 vs. 36 s, p = 0.013) and ROI3 (209 vs. 48 s, p = 0.001), lower normalized mean inflow slopes in ROI2 (2.4 vs 0.9%/s, p = 0.029) and ROI3 (4.2 vs. 1.6%/s, p = 0.002), and reduced mean outflow slopes in ROI3 (0.1 vs. 0.2, p = 0.021). Conventional clinical assessments failed to identify all compromised flaps. Conclusion
Q-ICG-FA objectively distinguished flaps with and without perfusion-related complications. Dynamic parameters, particularly Ttp and inflow/outflow slopes, were most associated with perfusion compromise. Larger studies are needed to validate these findings.
Cite this article
van 't Hof LWP, Nijssen DJ, van den Elzen RM, et al. Evaluating the potential of quantitative assessment of intraoperative fasciocutaneous flap perfusion using microscope-integrated indocyanine green fluorescence angiography. JPRAS Open. 2026. doi:10.1016/j.jpra.2026.01.008
Spotted a mistake? Suggest a correction