ResearchJPRAS Open · Jan 16, 2026

Evaluating the potential of quantitative assessment of intraoperative fasciocutaneous flap perfusion using microscope-integrated indocyanine green fluorescence angiography

van 't Hof LWP, Nijssen DJ, van den Elzen RM, van der Vorst JR, Hompes R, Bouman MB, et al
Plastic & Reconstructive SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗
Top Plastic & Reconstructive Surgery studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Abstract

Background Perfusion-related complications are a leading cause of morbidity and flap loss in reconstructive surgery. While indocyanine green fluorescence angiography (ICG-FA) is commonly used, its subjective interpretation may miss early signs of perfusion disturbances. Quantitative ICG-FA (Q-ICG-FA) offers a more objective method, but its potential in fasciocutaneous flaps remains insufficiently studied. Methods This retrospective study analyzed intraoperative ICG-FA data from patients undergoing fasciocutaneous flap reconstruction. Fluorescence-time curves (FTCs) were generated from three regions of interest (ROIs): reference tissue (ROI1), proximal flap (ROI2), and distal flap (ROI3). FTCs and derived quantitative parameters, including time-to-peak (Ttp) and normalized inflow/outflow slopes, were compared between patients with (PRC) and without (No PRC) perfusion-related complications. Results Twenty patients were included. Seven patients experienced a perfusion-related complication, most commonly venous congestion (n = 5). FTCs of compromised flaps showed delayed fluorescence peaks and reduced washout, most pronounced in ROI3. Quantitatively, the PRC group showed prolonged Ttp in ROI2 (105 vs. 36 s, p = 0.013) and ROI3 (209 vs. 48 s, p = 0.001), lower normalized mean inflow slopes in ROI2 (2.4 vs 0.9%/s, p = 0.029) and ROI3 (4.2 vs. 1.6%/s, p = 0.002), and reduced mean outflow slopes in ROI3 (0.1 vs. 0.2, p = 0.021). Conventional clinical assessments failed to identify all compromised flaps. Conclusion Q-ICG-FA objectively distinguished flaps with and without perfusion-related complications. Dynamic parameters, particularly Ttp and inflow/outflow slopes, were most associated with perfusion compromise. Larger studies are needed to validate these findings.

DOI: 10.1016/j.jpra.2026.01.008 · PubMed: 41696715

Cite this article

van 't Hof LWP, Nijssen DJ, van den Elzen RM, et al. Evaluating the potential of quantitative assessment of intraoperative fasciocutaneous flap perfusion using microscope-integrated indocyanine green fluorescence angiography. JPRAS Open. 2026. doi:10.1016/j.jpra.2026.01.008

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Plastic & Reconstructive Surgery

Research · Plast Reconstr Surg Glob Open · Nov 23, 2026 · Plastic & Reconstructive Surgery

The Evolving Role of Plastic Surgery in Inpatient Consultations: A 9-year Longitudinal Analysis of 4205 Consultations Across the COVID-19 Pandemic

Research · Plast Reconstr Surg Glob Open · Nov 20, 2026 · Plastic & Reconstructive Surgery

Autologous fat grafting improved radiation-induced skin changes in breast cancer patients

Research · Plast Reconstr Surg Glob Open · Nov 20, 2026 · Plastic & Reconstructive Surgery

Most cardiothoracic surgeons use wire cerclage for sternal closure, not rigid plate fixation

Research · Plast Reconstr Surg Glob Open · Nov 20, 2026 · Plastic & Reconstructive Surgery

Mailbox flap mastopexy technique corrects ptosis in 90.5% of patients

Research · Plast Reconstr Surg Glob Open · Nov 20, 2026 · Plastic & Reconstructive Surgery, Surgery

Surgical treatment satisfies patients with tuberous breast deformity regardless of psychiatric history