Evaluation of Chat Generative Pretrained Transformer's Performance in Cosmetic Injection Consultation by Authoritative Plastic Surgeons
Abstract
Background
ChatGPT (Chat Generative Pretrained Transformer), a large language model-based artificial intelligence, simulates doctor-patient communication. This study tested its applicability in injection-based cosmetic consultations using questions selected by 3 board-certified plastic surgeons with doctoral training and more than 10 years of experience at China's leading plastic surgery hospital. Methods
Professionalism and safety ratings were independently rated by 2 doctors for the test section and a third doctor for possible argument. Each question was asked 3 times independently to assess whether ChatGPT's performance on the same question was consistently satisfactory. Descriptive statistical analysis, multiple linear regression analysis, consistency analysis, 1-way analysis of variance, and repeated-measures analysis of variance were used to evaluate ChatGPT's safety, professionalism, empathy, and performance stability in this specific field. Results
ChatGPT showed 58.3% professionalism, 94.54% safety, and only 11.48% empathy, with lowest ratings for questions related to injection effects and wrinkles and highest ratings for failed repairs. Reproducibility was 65.57%, indicating stability. Empathetic and professional answers were usually more comprehensive, whereas inconsistent ones were correct but insufficient. Conclusions
By analyzing the assessment results of ChatGPT in terms of safety, professionalism, empathy, and performance stability, it is suggested that ChatGPT could potentially serve as an auxiliary tool to help doctors and patients improve treatment outcomes; however, efficiency and patient satisfaction were not directly measured in this study and should be validated in future prospective studies involving real patients.
Spotted a mistake? Suggest a correction
More in Plastic & Reconstructive Surgery
Releasable plating systems had higher complication rates than continuous systems
Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes
Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens
Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance
Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction
Most plastic surgery residents satisfied with elective rotation experience
Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training