Hypothermic machine perfusion was associated with lower risk of delayed graft function in kidney transplants
Ex vivo kidney machine perfusion: meta-analysis of randomized clinical trials
Meta-analysis of 16 randomized clinical trialsBenefit found
Does machine perfusion reduce delayed graft function compared to static cold storage?
Who
Deceased donor kidneys
Compared
Hypothermic machine perfusion: risk ratio 0.77
Static cold storage
Main outcome
delayed graft function
Result: risk ratio 0.77 (95% c.i. 0.69 to 0.86)
Bottom line: Hypothermic machine perfusion reduces the risk of delayed graft function compared to static cold storage.
Br J Surg · 2024-04-19 · Save PNG
Clinical question: Does machine perfusion reduce delayed graft function compared to static cold storage?
Key points
- Researchers analyzed 19 randomized clinical trials comparing machine perfusion to static cold storage, which is keeping organs in a cold environment.
- Hypothermic machine perfusion was associated with a lower risk of delayed graft function (risk ratio 0.77, 95% confidence interval 0.69 to 0.86).
- Full hypothermic machine perfusion decreased the risk of delayed graft function (risk ratio 0.69, 0.60 to 0.79), but partial hypothermic machine perfusion did not (risk ratio 0.92, 0.69 to 1.22).
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Was this summary helpful?
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Kang M, Kim S, Choi JY, et al. Ex vivo kidney machine perfusion: meta-analysis of randomized clinical trials. Br J Surg. 2024;111(4). doi:10.1093/bjs/znae102
Spotted a mistake? Suggest a correction