Visual abstractsVisuals
ResearchOTO Open · Sep 11, 2026

Exploring Complications of Orbital Floor Reconstructive Implants Using the MAUDE Database

Sagalow ES, Liu C, Alkhouri S, Ching HH
ENT (Otolaryngology)Adult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objective Orbital floor fractures are commonly treated with alloplastic implants, yet comparative safety data on implant materials remain limited. This study evaluates the adverse event (AE) profiles of commonly used orbital floor implants using a national device surveillance database. Study design Retrospective database analysis. Setting Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database. Methods The MAUDE database was queried for AEs related to 13 orbital floor reconstructive implants from 7 manufacturers. Reported events were categorized by implant type and classified as malfunction, injury, or other. Results A total of 90 AEs were identified across 4 implant types. Porous polyethylene SynPor® accounted for 69 events (76.7%), followed by porous polyethylene MEDPOR TITAN® with 15 (18.1%), porous polyethylene Su-Por® with 4 (4.8%), and smooth nylon foil SupraFOIL® with 2 (2.4%). Most AEs were categorized as malfunctions (n = 64, 77.1%), while 19 (21.1%) were reported as injuries. No malfunctions resulted in patient harm. All reported cases of implant infection or extrusion occurred with polyethylene implants. Overall, 97.6% of AEs involved polyethylene-based devices. No AEs were reported for titanium, poly-l/ dl-lactide, polycaprolactone, or PDS implants. Conclusion Within the MAUDE database, AEs were most frequently reported for porous polyethylene implants. These findings represent the first systematic characterization of MAUDE-reported AEs for orbital floor implants and identify porous polyethylene as the predominant implant type captured in national postmarket surveillance. Prospective comparative studies are needed to evaluate material-specific complication rates and further guide implant selection.

DOI: 10.1002/oto2.70301 · PubMed: 42730389

Cite this article

Sagalow ES, Liu C, Alkhouri S, Ching HH. Exploring Complications of Orbital Floor Reconstructive Implants Using the MAUDE Database. OTO Open. 2026. doi:10.1002/oto2.70301

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in ENT (Otolaryngology)

J Otolaryngol Head Neck Surg · Nov 24, 2026 · Research · ENT (Otolaryngology), Endocrinology & Diabetes

Hearing Loss in Morbid Obesity: Audiometric Findings and Risk Predictors

J Otolaryngol Head Neck Surg · Nov 24, 2026 · Research · ENT (Otolaryngology)

Survey of Canadian surgeons shows small workforce with limited specialized training and long wait times

J Otolaryngol Head Neck Surg · Nov 23, 2026 · Research · ENT (Otolaryngology), Anesthesiology

Inhaled methoxyflurane was associated with high completion rates during awake laryngeal procedures

OTO Open · Nov 22, 2026 · Research · ENT (Otolaryngology)

Gut fungal community changes and network instability were associated with chronic tinnitus

Laryngoscope Investig Otolaryngol · Nov 22, 2026 · Meta-analysis · ENT (Otolaryngology)

Laser therapy improved voice outcomes in vocal fold cyst patients