Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Atrial fibrillation (AF) is a common but often undetected cause of cryptogenic stroke (CS) and embolic stroke of undetermined source (ESUS). Implantable cardiac monitors aid in detecting subclinical AF, but their widespread use is limited by cost and logistical challenges. Several scoring systems exist to predict AF in patients with CS/ESUS, though few have been externally validated. This study was designed to externally validate 7 scoring systems for predicting incident AF in patients with CS/ESUS. Methods
In this observational study, we analyzed 132 patients with CS or transient ischemic attack who received implantable cardiac monitors. After a comprehensive literature search, 7 prediction models (Coronary Artery Disease or Chronic Obstructive Pulmonary Disease, Hypertension, Elderly, Systolic Heart Failure, Thyroid Disease [C2HEST], Brown ESUS-AF, ESUS-AF, Hypertension, Age, Valvular Heart Disease, Peripheral Vascular Disease, Obesity, Congestive Heart Failure, Coronary Artery Disease [HAVOC], Age, Hypercholesterolemia, Tricuspid Regurgitation, Left Ventricular End-Diastolic Volume, Left Atrium [ACTEL], Age, Stroke Severity, National Institutes of Health Stroke Scale >5 to Find Atrial Fibrillation [AS5F], and Coronary, Heart Failure, Age, Stroke Severity, Lipidemia, Sugar, Prior Stroke [CHASE-LESS]) were applied. The primary outcome was the discriminatory ability to detect AF. Secondary outcomes included evaluating the threshold scores and the performance of such threshold-based criteria for predicting nonoccurrence of AF with high specificity. Results
AF was detected in 40 patients (30.3%) over a mean follow-up of 13±12 months. Area under the receiver operating characteristic curves were C2HEST (0.704), Brown ESUS-AF (0.755), AS5F (0.726), ESUS-AF (0.607), HAVOC (0.661), ACTEL (0.650), and CHASE-LESS (0.671). C2HEST, Brown ESUS-AF, and AS5F showed acceptable predictive performance (area under the receiver operating characteristic curve >0.7). Threshold-based criteria using these scores achieved high specificity and positive predictive value. Combining thresholds across scores improved identification of patients unlikely to develop AF. Conclusions
C2HEST, Brown ESUS-AF, and AS5F scores reliably predicted AF in patients with CS/ESUS and may help identify low-risk individuals, supporting more targeted use of diagnostic tools and guiding stroke prevention strategies.
Topics
Spotted a mistake? Suggest a correction
More in Cardiology
Clonal hematopoiesis mutations linked to higher atrial fibrillation risk in cancer populations
Association of Clonal Hematopoiesis Mutations With Incident Atrial Fibrillation: A Systematic Review and Meta-Analysis
Deep learning model detects aortic stenosis from finger-cuff pressure waveforms accurately
Aortic Valve Stenosis Screening Using Deep Learning on Noninvasive Arterial Pressure Waveforms
Spontaneous coronary artery dissection affects younger women more often than expected
Spontaneous coronary artery dissection: implications for women's health, clinical care, and future research
Early lipid-lowering strategies may reduce atherosclerotic cardiovascular disease risk
Lipid-Lowering Strategies in the Era of Early Atherosclerosis Detection: 2026 ACC Scientific Statement: A Report of the American College of Cardiology