Introduction
Lowering extracorporeal circuit temperature (T°CRRT) below core temperature (T°CORE) during continuous renal replacement therapy (CRRT) may modify hemodynamic instability (HIRRT) risk by affecting cardiac output (CO) and vasomotor tone. This study aimed to identify the mediators involved in the relationship between CRRT-to-core temperature gradient and HIRRT risk. Methods
This ancillary analysis of a prospective, single-center center study (NCT03139123) included patients with stage 3 acute kidney injury, receiving CRRT for Results
42 patients were enrolled in this ancillary analysis (age 68 [58-76], SOFA 12 [8-15], 79% with sepsis), and were followed over 119 [57-143] hours (N = 1012 observations). Decreasing ΔT° (extracorporeal cooling) was significantly associated with higher heart rate, CO and MAP, lower norepinephrine dose, and was associated with a reduction in HIRRT risk in univariate analysis (P Conclusions
During CRRT, setting the circuit temperature below body temperature was associated with a reduced HIRRT risk, an effect potentially mediated through improvements in MAP and CO.
DOI: 10.1016/j.aicoj.2026.100108 · PubMed: 42471933 · Registered: NCT03139123
Spotted a mistake? Suggest a correction
More in Critical Care
Meta-analysisCrit Care · Nov 19, 2026 · Critical Care
Discordant evidence on corticosteroids in sepsis: a meta-research study
ResearchPediatricResuscitation · Nov 17, 2026 · Critical Care
Survival after neonatal chest compressions at birth: Temporal trends and prognostic factors in a population-based cohort, Queensland, Australia
ResearchResuscitation · Nov 17, 2026 · Critical Care
Survival after out of hospital cardiac arrest in relation to AED usage in a multi response system including AED equipped drones
ResearchResuscitation · Nov 17, 2026 · Critical Care
Out-of-hospital cardiac arrests due to foreign body airway obstruction: A CanROC registry, retrospective cohort study
ResearchResuscitation · Nov 17, 2026 · Critical Care