ResearchResuscitation Plus · Sep 21, 2026

Feasibility and placement accuracy of a sensor-guided intraosseous device with an automated stop in a small-bone rat cadaver model: a single-arm pilot study

Ortner M, Hacker C, Kaider A, Stanek J, Russ D, Unger E, et al
Emergency MedicineBasic science

Study type: Laboratory or animal research: results may not apply to people yet.

Read the full paper free at PubMed Central ↗

Abstract

Background Rapid intraosseous (IO) access is critical in emergency care when venous access is not feasible. IO access is particularly prone to error in small animals and human neonates with narrow medullary cavities. This pilot study evaluated the feasibility and placement accuracy of a novel sensor-guided IO drilling device with an automatic stop mechanism in a rat cadaver model. Methods Seven thawed Sprague-Dawley rat cadavers underwent 14 tibial insertions by a single experienced operator using a standardised protocol. Placement was assessed by computed tomography (CT), with successful insertion defined as intramedullary positioning of the needle tip. Two blinded readers independently classified each insertion. The principal outcome was the proportion of successful placements; a prespecified device-evaluable analysis excluding user-related targeting errors was exploratory. Results Nine of 14 insertions were correctly positioned, yielding a success rate of 64.3% (9/14; 95% CI 35.1-87.2%). In the device-evaluable analysis, success was 81.8% (9/11; 95% CI 48.2-97.7%). Three lateral displacements and two overpenetrations occurred. Reader agreement was complete (κ = 1.00). The medullary cavity narrowed from 6.02 mm at the proximal metaphysis to 3.13 mm at the diaphysis, with cortical thickness of 0.54-0.57 mm; proximal epiphyseal outer diameter of 8.07 mm. No device malfunction was identified. Conclusion In this small-bone cadaver model, the automated-stop intraosseous device achieved CT-verified intramedullary placement in most attempts and functioned as intended. As this single-arm pilot lacked a comparator and CT assessed needle-tip position rather than functional access, the findings are limited to placement accuracy and are hypothesis-generating.

DOI: 10.1016/j.resplu.2026.101500 · PubMed: 42871938

Cite this article

Ortner M, Hacker C, Kaider A, Stanek J, Russ D, Unger E. Feasibility and placement accuracy of a sensor-guided intraosseous device with an automated stop in a small-bone rat cadaver model: a single-arm pilot study. Resusc Plus. 2026. doi:10.1016/j.resplu.2026.101500

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

More in Emergency Medicine

Meta-analysis · J Med Internet Res · Nov 23, 2026 · Digital Health & AI, Emergency Medicine

Large language models mainly used for documentation in emergency departments

Research · BMJ Med · Nov 18, 2026 · Emergency Medicine

Direct admission to level 1 trauma centre was linked to lower 30 day mortality

Research · Am J Emerg Med · Nov 13, 2026 · Emergency Medicine, Hematology

Emergency department blood transfusions were associated with longer stays and higher rates of return

Research · J Med Internet Res · Nov 13, 2026 · Digital Health & AI, Emergency Medicine

Physicians often intend to act on false information in AI-generated abstracts

Research · Am J Emerg Med · Nov 12, 2026 · Emergency Medicine, Neurology

Serum lactate levels were associated with different types of neurologic emergencies in emergency department patients