ResearchJACC: Advances · Oct 5, 2026

Feasibility and Safety of Transthoracic Echocardiography-Guided Transvenous Permanent Pacemaker Implantation Without Fluoroscopy

Feng T, Li Z, Dong J, Zhao G, Wang C, Dong J, et al
CardiologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background Fluoroscopy is routinely used for transvenous permanent pacemaker implantation, but a standardized transthoracic echocardiography (TTE)-only workflow has not been prospectively evaluated. Objectives The objective of the study was to evaluate the feasibility, acute safety, and procedural performance of fluoroscopy-free transvenous pacemaker implantation guided exclusively by TTE. Methods In this prospective, single-center feasibility study (RADIANCE [Radiation-free Anatomical Direct Imaging Approach for No-fluoroscopy Cardiac Electrode Implantation]; NCT07458724), 52 consecutive patients referred to the Department of Structural Heart Disease were screened. Thirty-one selected patients (59.6%) with guideline-based pacing indications and adequate prespecified supine TTE acoustic windows underwent attempted TTE-only implantation. Acute procedural success required completion without fluoroscopic conversion and fulfillment of prespecified TTE-defined anatomical, electrical, and safety criteria. Results TTE-only implantation was successful in 30/31 patients (96.8%; 95% CI: 83.3-99.9), with fluoroscopic conversion in 1/31 (3.2%). The mean procedure time was 55.4 ± 5.6 minutes. No major acute procedural complications occurred. During a median follow-up of 8.8 months (IQR: 6-12 months), atrial lead dislodgement requiring revision occurred in 1/21 dual-chamber recipients (4.8%; 95% CI: 0.1-23.8). Procedure time decreased with chronological case order (-0.59 minutes/case; Newey-West 95% CI: -0.68 to -0.49), an exploratory team-level association. Conclusions In selected patients with adequate supine acoustic windows, TTE-guided fluoroscopy-free pacemaker implantation was feasible with acceptable acute outcomes. The lead-position findings and exploratory case-order association require further validation in larger and more diverse populations.

DOI: 10.1016/j.jacadv.2026.103301 · PubMed: 42832919 · Registered: NCT07458724

Cite this article

Feng T, Li Z, Dong J, et al. Feasibility and Safety of Transthoracic Echocardiography-Guided Transvenous Permanent Pacemaker Implantation Without Fluoroscopy. JACC Adv. 2026;5(11 Pt 2):103301. doi:10.1016/j.jacadv.2026.103301

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Cardiology studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

More in Cardiology

Research · JACC Adv · Nov 26, 2026 · Cardiology

No significant rise in anti-gal IgE found after bioprosthetic aortic valve replacement

Research · JACC Adv · Nov 26, 2026 · Cardiology, Nephrology

Pecavaptan linked to lower kidney function and higher urine albumin in heart failure

Research · JACC Adv · Nov 26, 2026 · Cardiology

Expert panel proposes framework for interventional heart failure specialist training

Research · JACC Adv · Nov 26, 2026 · Cardiology, Psychiatry & Mental Health

Mental health burden linked to lower angina improvement in ANOCA patients

Research · JACC Adv · Nov 26, 2026 · Cardiology, Medical Genetics & Genomics

Rare genetic variants found in nearly 60% of Swedish SCAD patients