Frailty Status Modifies the Efficacy of ICD Therapy for Primary Prevention Among Patients With HF
Key result: Frailty status affects whether implantable cardioverter-defibrillators reduce death risk in heart failure patients
Randomized trial analysisMixed results
Does frailty status modify the efficacy of implantable cardioverter-defibrillator therapy for primary prevention?
Who
1676
Participants with heart failure with reduced ejection fraction
Compared
Low frailty burden: hazard ratio 0.56 (95% CI 0.40-0.78)
High frailty burden: hazard ratio 0.86 (95% CI 0.68-1.09)
Main outcome
all-cause mortality
Result: Pinteraction = 0.047
Bottom line: Implantable cardioverter-defibrillator therapy benefits mortality in low frailty patients but not in high frailty patients.
JACC Heart Fail · 2023-08-09 · Save PNG
Key points
- Researchers analyzed 1,676 participants from the Sudden Cardiac Death in Heart Failure Trial who had heart failure with reduced ejection fraction.
- Implantable cardioverter-defibrillator therapy was associated with a lower risk of all-cause mortality in patients with low frailty (HR: 0.56; 95% CI: 0.40-0.78).
- No significant mortality benefit from the device was observed among patients with a high frailty burden (HR: 0.86; 95% CI: 0.68-1.09).
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: Segar MW, Keshvani N, Singh S, et al. Frailty Status Modifies the Efficacy of ICD Therapy for Primary Prevention Among Patients With HF. JACC Heart Fail. 2024;12(4):757-767. doi:10.1016/j.jchf.2023.06.009
Free full text: JACC Heart Fail website · Summary and visual abstract: nowallmed.com/a/frailty-status-modifies-the-efficacy-of-icd-therapy-for-primary-1gfwoio/ (AI-assisted from the abstract; check the paper before relying on it).