Automated software provides fast and accurate diaphragm segmentation on 2D and 3D thoracic MRI
Fully automated diaphragm segmentation on routine 2D-cine and 3D thoracic MRI: multireader validation
Why it matters: Manual segmentation of the diaphragm on magnetic resonance imaging is a time-consuming process that limits parametric assessment.
- Researchers studied 59 adults to compare automated diaphragm segmentation against manual tracing on 2D-cine and 3D magnetic resonance imaging (MRI).
- The automated process took 5 s for 2D and 30 s for 3D, compared to 10 min for 2D and 4.5 h for 3D manual annotation.
- Segmentation accuracy was high with a normalized surface Dice of 0.95 ± 0.08 for 2D and 0.92 ± 0.06 for 3D.
Limitation the authors note: The study was a single-center study and requires larger multicenter validation.
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Topics
Cite this article
Boussouar S, Pasquier A, Vaurs D, Douho Kamta AD, Reitmann A, Pasi N. Fully automated diaphragm segmentation on routine 2D-cine and 3D thoracic MRI: multireader validation. Eur Radiol Exp. 2026. doi:10.1186/s41747-026-00805-z
Spotted a mistake? Suggest a correction