Visual abstractsVisuals
ResearchAesthetic Surgery Journal · Aug 22, 2026

Functional Performance, Subject-body Perception, and Safety Following Multi-muscle Electromuscular Stimulation: A Randomized Controlled Study

Movassaghi K, Marashi N, Mann S, Amir R
Plastic & Reconstructive SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Background Electromuscular stimulation (EMS) and high-intensity focused electromagnetic technologies are widely used for non-invasive muscle strengthening and body contouring. Most available EMS devices induce repetitive contractions of isolated muscle groups resulting in increased muscle thickness and improved aesthetic outcome. However, the current literature is lacking evidence to support functional performance gain following EMS treatments. Objectives To evaluate functional performance outcomes following treatment with a novel EMS technology. based on synchronized multi-muscle activation and regulated contraction duty cycles. Methods Thirty-eight healthy adult subjects were equally randomized to treatment and blank control cohorts. The study was conducted between July 2025 and January 2026. The treatment protocol included six weekly sessions targeting abdominal, quadriceps, hamstring, and gluteal muscle groups. Functional performance assays included prone hip extension repetitions to measure gluteus, paced curl-up performance and side plank endurance to measure abdominal muscles and seated quadriceps extension repetitions for measuring quadriceps strength. Subject reported body perception was documented. Outcome measures were performed at baseline, week 5 (pre-last treatment), and week 9 (4 weeks post last treatment). Subjects' performance over time and comparisons between groups were analyzed. Results The treatment group demonstrated statistically significant gain in repetition-based and endurance-based performance measures compared with baseline and control subjects. Improvements were maintained through the 4-week follow-up. Treated subjects body self perception was improved. The procedure was well tolerated, with low discomfort and no reported adverse events. Conclusions Treatment with PlyoPulse technology was associated with measurable improvements in functional performance, enhanced body self perception and a favorable safety profile. The findings suggest that stimulation patterns incorporating a programmable synchronized multi muscles activation may better enhance coordinated neuromuscular recruitment consistent with exercise physiology.

DOI: 10.1093/asj/sjag167 · PubMed: 42631368

Spotted a mistake? Suggest a correction

More in Plastic & Reconstructive Surgery

ResearchPlast Reconstr Surg Glob Open · Nov 19, 2026 · Plastic & Reconstructive Surgery

Robotic Versus Endoscopic Approach in Single-port Nipple-sparing Mastectomy With Direct-to-implant Prepectoral Breast Reconstruction

Meta-analysisPlast Reconstr Surg Glob Open · Nov 19, 2026 · Plastic & Reconstructive Surgery

Releasable plating systems had higher complication rates than continuous systems

Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes

ResearchPlast Reconstr Surg Glob Open · Nov 18, 2026 · Plastic & Reconstructive Surgery

Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens

Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance

ResearchPlast Reconstr Surg Glob Open · Nov 18, 2026 · Plastic & Reconstructive Surgery

Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction

ResearchPlast Reconstr Surg Glob Open · Nov 18, 2026 · Plastic & Reconstructive Surgery

Most plastic surgery residents satisfied with elective rotation experience

Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training