Functional Performance, Subject-body Perception, and Safety Following Multi-muscle Electromuscular Stimulation: A Randomized Controlled Study
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Electromuscular stimulation (EMS) and high-intensity focused electromagnetic technologies are widely used for non-invasive muscle strengthening and body contouring. Most available EMS devices induce repetitive contractions of isolated muscle groups resulting in increased muscle thickness and improved aesthetic outcome. However, the current literature is lacking evidence to support functional performance gain following EMS treatments. Objectives
To evaluate functional performance outcomes following treatment with a novel EMS technology. based on synchronized multi-muscle activation and regulated contraction duty cycles. Methods
Thirty-eight healthy adult subjects were equally randomized to treatment and blank control cohorts. The study was conducted between July 2025 and January 2026. The treatment protocol included six weekly sessions targeting abdominal, quadriceps, hamstring, and gluteal muscle groups. Functional performance assays included prone hip extension repetitions to measure gluteus, paced curl-up performance and side plank endurance to measure abdominal muscles and seated quadriceps extension repetitions for measuring quadriceps strength. Subject reported body perception was documented. Outcome measures were performed at baseline, week 5 (pre-last treatment), and week 9 (4 weeks post last treatment). Subjects' performance over time and comparisons between groups were analyzed. Results
The treatment group demonstrated statistically significant gain in repetition-based and endurance-based performance measures compared with baseline and control subjects. Improvements were maintained through the 4-week follow-up. Treated subjects body self perception was improved. The procedure was well tolerated, with low discomfort and no reported adverse events. Conclusions
Treatment with PlyoPulse technology was associated with measurable improvements in functional performance, enhanced body self perception and a favorable safety profile. The findings suggest that stimulation patterns incorporating a programmable synchronized multi muscles activation may better enhance coordinated neuromuscular recruitment consistent with exercise physiology.
Spotted a mistake? Suggest a correction
More in Plastic & Reconstructive Surgery
Releasable plating systems had higher complication rates than continuous systems
Continuous Versus Releasable Plating Systems for Sternal Closure: A Systematic Review of Outcomes
Saphenous nerve terminated near navicular cuneiform joint in 45% of specimens
Evaluating Saphenous Nerve Variations With Classification System in the Lower Limb, an Anatomical Study With Surgical Relevance
Evaluation of an Animated Patient Information Video: Improving Consent and Decision-making for Deep Inferior Epigastric Perforator Flap Breast Reconstruction
Most plastic surgery residents satisfied with elective rotation experience
Optimizing the Chief Resident Elective Rotation: Insights From Alumni Feedback in Plastic Surgery Training