ResearchResuscitation · Jun 8, 2026

Gentle limb fixation for a faster reliable heart rate obtained with pulse oximeter at birth

Bloemhof MM, Dekker J, van den Berg SMA, Koster R, Cramer SJE, Te Pas AB
Critical CareCardiologyPediatric
Read the full paper free at the publisher ↗

Abstract

Aim Pulse oximetry is widely used to monitor heart rate (HR) and peripheral oxygen saturation during neonatal resuscitation. As HR is a key parameter guiding clinical decision-making during initial assessment and stabilization, timely and accurate HR readings are critical. However, it can take minutes to achieve a reliable reading directly after birth. This study aimed to determine whether infant limb movement and gentle fixation after pulse-oximeter application influence the time to obtain the first reliable HR. Methods Video recordings of neonatal resuscitations with simultaneous pulse oximetry readings were retrospectively analyzed for neonates ≥24 weeks' gestation. Neonates were categorized into three groups based on the status of the right limb during the first 10 s after sensor application: (1) movement, (2) no movement, or (3) gentle fixation by a caregiver. Time to the first reliable HRPO was determined using a custom-developed, ECG-validated algorithm applied to the photoplethysmogram. Results A total of 178 neonates were included, with a median gestational age of 30 + 4 weeks (28 + 4-33 + 6), with no significant differences between groups. Median time to achieve a reliable HRPO was significantly shorter in the "no movement" (20.3 [16.1-34.2] s) and "fixation" (17.9 [14.9-25.4] s) groups as compared to the "movement" group (46.2 [23.5-75.1] s) (p < 0.001). The percentage of neonates who achieved a reliable HRPO within 30 s after application was significantly higher after limb fixation (80.5%) versus no fixation (49.6%) (p < 0.001). Conclusion Pulse oximetry does not seem motion artefact resistant when the first HR is obtained. Gentle limb fixation after sensor application may facilitate more timely clinical assessment.

Subject terms

Humans; Oximetry; Infant, Newborn; Heart Rate; Retrospective Studies; Female; Male; Time Factors; Resuscitation; Oxygen Saturation; Video Recording; Extremities

DOI: 10.1016/j.resuscitation.2026.111164 · PubMed: 42264172

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Bloemhof MM, Dekker J, van den Berg SMA, Koster R, Cramer SJE, Te Pas AB. Gentle limb fixation for a faster reliable heart rate obtained with pulse oximeter at birth. Resuscitation. 2026;225:111164. doi:10.1016/j.resuscitation.2026.111164

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Critical Care studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Meta-analysis n = 240 · Crit Care · May 26, 2023 · Critical Care

Changes in central venous oxygen saturation may identify patients who respond to fluid treatment

Research · BMJ · Jan 14, 2026 · Infectious Disease, Critical Care

The impact of skin tone on performance of pulse oximeters used by NHS England COVID Oximetry @home scheme: measurement and diagnostic accuracy study

Randomized trial n = 1,960 · BMJ · Mar 24, 2025 · Cardiology, Cardiothoracic & Vascular Surgery

Monitoring tissue oxygen levels did not reduce postoperative complications after off-pump heart bypass surgery

Clinical trial · Chest · Mar 30, 2026 · Pulmonology, Cardiology

Effects of a Sea-Level Stay on Pulmonary Hemodynamics in Patients With Pulmonary Arterial Hypertension Living in Quito Near 2,850 m

Meta-analysis · Anaesthesia · Aug 10, 2022 · Anesthesiology, Digital Health & AI

Wearable and contactless devices showed similar accuracy for monitoring vital signs in clinical settings