ResearchEJNMMI Research · Nov 28, 2025

Global and regional accuracy of deep learning-based tumor segmentation from whole-body [18F]fluorodeoxyglucose PET/CT images

Ciarmiello A, Yosifov N, Masciale D, Ferrando O, Foppiano F, Milano A, et al
Radiology & ImagingDigital Health & AIAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Background The number of [¹⁸F]fluorodeoxyglucose ([¹⁸F]FDG)-PET/CT scans performed has significantly increased in the last decade in line with the increasing trend of oncological malignancies. Such images, which signal high glucose-uptake areas are key in defining the extent of the disease, staging and response to therapy. Processing and evaluation of ([¹⁸F]FDG)-PET/CT scans, however, require manual annotation by well-trained specialists and above all time. In time and resource-constrained settings meeting the increasing demand for PET/CT scans has become challenging. The main goal of our study was to test the relationship between the volumes predicted by the deep learning algorithm and the manually segmented ones. The secondary objective goal was to measure the extent at which the predictive accuracy is associated with normal background uptake. Results The study sample included 1334 [¹⁸F]FDG-PET/CT scans from subjects with histologically confirmed diagnoses of lung cancer, lymphoma, and melanoma. 933 (70%) [¹⁸F]FDG-PET/CT scans were used as the training dataset and 267 (20%) scans were used as an internal validation dataset. A subsample of 134 (10%) [¹⁸F]FDG-PET/CT scans not used for training was used as the test dataset. The segmentation model was implemented with the nnU-Net convolutional network available in the MONAI framework. Model performance was measured with the Dice score. Correlation between manual and predicted segmentation was assessed using linear correlation. Totalsegmentator tool was used to identify lesions location and assess the tumor-to-background ratio (TBR) for quantitative analysis. Network achieved Dice scores of 0.918 (validation) and 0.879 (test), showing strong agreement with manual segmentations. The model achieved an F1 score of 0.91 on the test set. High correlation (R=0.82, p<0.0001) was observed between predicted and ground truth volumes. Segmentation accuracy improved with higher TBRs, as lesions with TBR>2 had significantly better Dice scores than those with lower contrast (TBR ≤ 1-2 or≤1). Conclusions These results are consistent with previous reports on PET-based segmentation, further validating nnU-Net as a reliable approach for detecting hypermetabolic lesions and assessing global disease burden in FDG-PET imaging. Moreover, the significant relationship between TBR and segmentation accuracy suggests the possibility of further improvements by integrating metabolic profile into the predictive model.

More on this topic

AI in medicine

DOI: 10.1186/s13550-025-01333-4 · PubMed: 41313553

Cite this article

Ciarmiello A, Yosifov N, Masciale D, Ferrando O, Foppiano F, Milano A. Global and regional accuracy of deep learning-based tumor segmentation from whole-body [18F]fluorodeoxyglucose PET/CT images. EJNMMI Res. 2025. doi:10.1186/s13550-025-01333-4

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

More in Radiology & Imaging

Research · eBioMedicine · Nov 24, 2026 · Neurology, Radiology & Imaging

Brain and spinal cord inflammation are linked and brain lesions predict spinal cord thinning

Research · Insights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Meta-analysis · Eur Radiol Exp · Nov 20, 2026 · Radiology & Imaging, Oncology

No pancreatic tumor MRI radiomics studies reported all necessary imaging parameters for reproducibility

Research · Arthritis Res Ther · Nov 20, 2026 · Rheumatology, Radiology & Imaging

Siglec-9 PET/CT imaging was associated with higher tracer uptake in patients with polymyalgia rheumatica

Research · Insights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity