Introduction
Health care accounts for nearly 5% of global greenhouse gas emissions, and medical imaging is among its most energy-intensive activities. For intermediate-likelihood common bile duct stones, endoscopic ultrasound (EUS) and magnetic resonance cholangiopancreatography (MRCP) are both guideline-endorsed with comparable diagnostic accuracy, yet their environmental costs have never been directly compared. Methods
In this prospective study, we measured the per-procedure carbon footprint of EUS and MRCP using the Greenhouse Gas Protocol and India's grid emission factor. We recorded EUS procedure times individually; MRCP emissions were derived from a validated power model that captures the continuous cryocooler load maintaining magnet superconductivity around the clock, with shared infrastructure allocated by real case volume. We performed sensitivity analyses across scanner utilization, energy-allocation method, scan duration, and grid carbon intensity. The study followed the European Society of Gastrointestinal Endoscopy Endoscopic Sustainability PrimAry Reporting Essentials reporting standard. Results
EUS generated 4.53 kg CO 2 e per procedure and MRCP 18.90 kg CO 2 e per procedure, making MRCP 4.2 times more carbon-intensive. The continuously running cryocooler was the single largest fixed contributor to MRCP emissions (23.4% in standby alone), a 24/7 load absent in EUS. Choosing EUS for 108 patients saved 1,552 kg CO 2 e, equivalent to the annual carbon uptake of 74 mature trees. EUS remained the lower-carbon option across sensitivity analyses, although the advantage narrowed and could reverse on low-carbon grids. Discussion
For bile duct stone evaluation, EUS offers the same diagnostic answer at substantially lower carbon cost where grid electricity is carbon-intensive, adding environmental impact to accuracy, safety, and cost in the decision.
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Rughwani H, Jagtap N, de Jong DM, et al. Greener Choices in Biliary Imaging: A Prospective Carbon Footprint Comparison of Endoscopic Ultrasound Versus Magnetic Resonance Cholangiopancreatography for Intermediate-Likelihood Choledocholithiasis. Clin Transl Gastroenterol. 2026;17(10):e01098. doi:10.14309/ctg.0000000000001098