Randomized trialEuropean Respiratory Journal · May 26, 2022

Guide sheath versus non-guide sheath method for endobronchial ultrasound-guided biopsy of peripheral pulmonary lesions: a multicentre randomised trial

Oki M, Saka H, Imabayashi T, Himeji D, Nishii Y, Nakashima H, et al
PulmonologyPathology & Laboratory MedicineAdult
Read the full paper free at the publisher ↗

Abstract

Background Guide sheaths (GSs) have been widely used during radial probe endobronchial ultrasound-guided transbronchial biopsy (rEBUS-TBB) of peripheral pulmonary lesions. However, it remains unknown whether a GS enhances the diagnostic yield. We compared the diagnostic yields of small peripheral pulmonary lesions between rEBUS-TBB with and without a GS. Methods In eight institutions, patients with peripheral pulmonary lesions ≤30 mm in diameter were enrolled and randomised to undergo rEBUS-TBB with a GS (GS group) or without a GS (non-GS group) using a 4.0-mm thin bronchoscope, virtual bronchoscopic navigation and fluoroscopy. The primary end-point was the diagnostic yield of the histology specimens. Results A total of 605 patients were enrolled; ultimately, data on 596 (300 in the GS group and 296 in the non-GS group) with peripheral pulmonary lesions having a longest median diameter of 19.6 mm were analysed. The diagnostic yield of histological specimens from the GS group was significantly higher than that from the non-GS group (55.3% versus 46.6%; p=0.033). Interactions were evident between the diagnostic yields, procedures, lobar locations (upper lobe versus other regions; p=0.003) and lesion texture (solid versus part-solid nodules; p=0.072). Conclusions The diagnostic yield for small peripheral pulmonary lesions afforded by rEBUS-TBB using a GS was higher than that without a GS.

Topics

Biopsy; Bronchoscopy; Endosonography; Humans; Image-Guided Biopsy; Lung; Lung Neoplasms; Ultrasonography, Interventional

DOI: 10.1183/13993003.01678-2021 · PubMed: 34625482

Cite this article

Oki M, Saka H, Imabayashi T, Himeji D, Nishii Y, Nakashima H. Guide sheath versus non-guide sheath method for endobronchial ultrasound-guided biopsy of peripheral pulmonary lesions: a multicentre randomised trial. Eur Respir J. 2022. doi:10.1183/13993003.01678-2021

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, by email. Free.

Get the weekly digest

Similar articles

Research · Respir Res · May 9, 2026 · Pulmonology, Infectious Disease

Pulmonary infectious complications associated with the addition of cryobiopsy to conventional sampling for peripheral pulmonary lesions: a retrospective study

Research · NEJM · May 18, 2025 · Pulmonology

Navigational Bronchoscopy or Transthoracic Needle Biopsy for Lung Nodules

Research · Chest · Mar 25, 2026 · Pulmonology, Radiology & Imaging

Cone Beam CT Imaging-Guided Bronchoscopy vs CT Imaging-Guided Transthoracic Needle Biopsy for Peripheral Pulmonary Lesion Diagnosis

Research · Respir Res · May 11, 2026 · Pulmonology

Robotic-assisted bronchoscopy-guided cryobiopsy for the diagnosis of ground-glass opacity-predominant peripheral pulmonary nodules

Meta-analysis · Chest · Jan 11, 2023 · Pulmonology

Guided Bronchoscopy for the Evaluation of Pulmonary Lesions: An Updated Meta-analysis