Randomized trialAnnals of Intensive Care · Apr 9, 2026
High-frequency oscillation improves mucus clearance and airway resistance in mechanically ventilated patients: a randomized clinical trial
Wang Y, Chen D, Xie W, Zhang R, Guo X, Wu H, et al
Abstract
Background
Mechanical ventilation is associated with both impaired ciliary function and a weakened cough, which further impair secretion clearance. Continuous high-frequency oscillation (CHFO) is a promising technique to reduce respiratory muscle loading and facilitate secretion clearance in mechanically ventilated patients. The aim of this study was to assess the effect of CHFO on airway resistance (Raw). Methods
This is a prospective, randomized controlled trial conducted in a 60-bed ICU between April 2023 and March 2024. Mechanically ventilated patients with excessive airway secretions (defined as the sputum volume exceeding 150 ml within the past 24 hours) were randomly assigned to either receive CHFO for 10 minutes followed by secretion aspiration (CHFO group), or to undergo secretion aspiration alone (control group). Throughout the study, only the study intervention and necessary suctioning were performed, and patient positioning and ventilator settings were kept constant. Arterial blood gases, respiratory mechanics, and the percentage of dorsal lung ventilation (assessed by electrical impedance tomography) were measured in both groups at four timepoints: pre-intervention (baseline), immediately post-intervention (T0), one-hour post-intervention (T1), and three-hours post-intervention (T3). The primary outcome was the change in Raw from baseline at each time point (ΔRaw: Rpost-intervention - Rbaseline). Change in respiratory system compliance (Crs), and ventilation distribution were also recorded. Results
46 patients, with a median sputum volume of 160 ml over the last 24 hours, were enrolled. Baseline characteristics were well-balanced in the two groups. CHFO group showed a significantly larger decrease in Raw compared to control group at T1 (CHFO: -2.4 ± 1.8 vs. control: -0.1 ± 1.6 cmH₂O/L·s, p Conclusions
In mechanically ventilated patients with excessive airway secretions, the reduction in Raw from baseline was significantly greater in the CHFO group than control group at one-hour and three-hour post-intervention.
DOI: 10.1016/j.aicoj.2026.100062 · PubMed: 42005528
Spotted a mistake? Suggest a correction
More in Critical Care
Meta-analysisCrit Care · Nov 19, 2026 · Critical Care
Discordant evidence on corticosteroids in sepsis: a meta-research study
ResearchPediatricResuscitation · Nov 17, 2026 · Critical Care
Survival after neonatal chest compressions at birth: Temporal trends and prognostic factors in a population-based cohort, Queensland, Australia
ResearchResuscitation · Nov 17, 2026 · Critical Care
Survival after out of hospital cardiac arrest in relation to AED usage in a multi response system including AED equipped drones
ResearchResuscitation · Nov 17, 2026 · Critical Care
Out-of-hospital cardiac arrests due to foreign body airway obstruction: A CanROC registry, retrospective cohort study
ResearchResuscitation · Nov 17, 2026 · Critical Care