Meta-analysisJournal of Medical Internet Research · Apr 29, 2026
Image-Based Deep Learning for Cataract Diagnosis: Systematic Review and Meta-Analysis
Li R, Li H, Li C, Li S, Lei L, Tao D
Abstract
Background
Cataracts are an eye condition characterized by high prevalence and blindness-inducing potential, and effective approaches are required for their early diagnosis, underscoring the clinical significance of this study. Objective
This study aims to evaluate the performance of deep learning (DL) in cataract diagnosis and assess its potential as an effective tool for automated diagnosis, and compare the diagnostic accuracy of DL versus both machine learning and human experts. Methods
A systematic search was conducted in Web of Science, Embase, IEEE Xplore, PubMed, and Cochrane Library until April 1, 2025, for studies on image-based DL for cataract detection or clinical subtype classification. The included studies were assessed for the risk of bias (RoB) using Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2). Bivariate mixed effects models were used for data analyses, and publication bias was assessed by Deeks' funnel plots. Results
Sixty-three studies were finally included. The quality assessment indicated a high or unclear RoB in the patient selection (34 studies) and index test (44 studies) domains. Meanwhile, in the reference standard domain, the risk of bias was high or unclear in only 2 studies. Image-based DL achieved a sensitivity of 96% (95% CI 0.95-0.97) and a specificity of 98% (0.96-0.98) for cataract detection, with an area under the ROC curve (AUC) of 0.99 (0.98-1.00). For cataract classification, the sensitivity and specificity of image-based DL were 94% (0.93-0.96) and 97% (0.96-0.98), respectively, with an AUC of 0.99 (0.98-0.99). Despite the strong overall performance, the model's generalization capability was challenged by its lower performance observed on independent external datasets (detection: sensitivity 87%, specificity 93%; classification: sensitivity 89%, specificity 90%), potentially attributable to domain shift between the training and validation data. Conclusions
Image-based DL has demonstrated high precision in the detection and classification of cataracts, showing potential advantages over traditional machine learning methods, though validation remains limited. Its performance falls within the range of reported accuracy of human experts, highlighting the high feasibility of automated diagnosis. However, validation data limitations, coupled with moderate-quality evidence and high heterogeneity, constrain the utility of DL in auxiliary diagnosis. The model's sensitivity dropped to 87% in external validation, restricting its generalization capability, so caution should be exercised in broad clinical implementation.
Topics
Deep Learning; Cataract; Humans
DOI: 10.2196/78869 · PubMed: 42054635
Spotted a mistake? Suggest a correction
More in Digital Health & AI
ResearchLancet Digit Health · Nov 23, 2026 · Digital Health & AI
ClinicalAge, a framework for modelling ageing trajectories from longitudinal electronic health records in the UK: a model development and validation study
ResearchLancet Digit Health · Nov 23, 2026 · Digital Health & AI
Foundation artificial intelligence models for health recognition by use of face photographs (FAHR-Face): a model development and validation study
ResearchLancet Digit Health · Nov 23, 2026 · Digital Health & AI
A prognostic model for use at labour onset to estimate the risk of severe fetal compromise at birth: a retrospective, model development and validation study
ResearchNPJ Digit Med · Nov 21, 2026 · Digital Health & AI
ECG foundation models for cardiovascular screening in a cohort of young competitive athletes
ResearchJ Med Internet Res · Nov 20, 2026 · Digital Health & AI
Medical Reasoning in Large Language Models: Development and Evaluation of the MedEvalArena Benchmark