Visual abstractsVisuals
ResearchJournal of Nuclear Medicine · Apr 1, 2026

Imaging Microtubule Dynamics In Vivo in Human Brain: Optimal Quantification Based on a Test-Retest Study

Zanderigo F, Laurell GL, Doubrovin M, Molotkov A, Ali A, Arevalo RF, et al
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Microtubules are cytoskeletal components that play essential roles in the brain, including supporting neuronal structure, protein transport, and cognitive function. In vivo quantification of microtubule dynamics using PET is possible with 11C-MPC6827, a brain-penetrant radiotracer that has been evaluated in mice and nonhuman primates. Here we present the first assessment of 11C-MPC6827 test-retest properties in a healthy human brain and examine the influence of scan duration on repeatability. Methods: Five healthy volunteers underwent two 90-min 11C-MPC6827 PET scans with concurrent arterial blood sampling (4 imaged twice in 1 d, 1 rescanned after 1 y). Radiotracer time-activity curves were extracted from 46 individual brain regions, in addition to the whole brain. Total distribution volume (V T) was estimated using kinetic models and graphical analysis. SUVs and the SUV ratio to whole brain (SUVRWB) were computed in 2 postinjection time windows. Repeatability was assessed using absolute test-retest percent difference (TRPD) and intraclass correlation coefficient (ICC). Time stability was examined by truncating imaging data from 90-min to 60-min acquisition and comparing computed outcomes to the 90-min value as gold standard. Results: V T estimates were stable with truncated scan time (average shorter V T/90-min V T, 1.003-1.030). For the same-day test-retest pairs, V T estimates obtained with kinetic models showed average TRPD values, across regions and participants, between 10.18% and 14.26%, and ICCs between 0.483 and 0.966. Graphical approaches demonstrated lower repeatability than kinetic models. Across methods, TRPDs were lower and ICCs were higher with shorter scans. SUV showed higher interscan variability in TRPD. SUVRWB was more stable (TRPD, 2.22%-5.47%) and less influenced by scan duration. However, ICCs were overall much lower for SUV and SUVRWB than for V T Conclusion: 11C-MPC6827 shows good repeatability for quantifying microtubule dynamics in humans using arterial blood even at a 60-min scan duration. SUVRWB could be a convenient blood-free alternative to V T.

Topics

Humans; Brain; Positron-Emission Tomography; Microtubules; Male; Adult; Reproducibility of Results; Female; Radiopharmaceuticals; Carbon Radioisotopes; Image Processing, Computer-Assisted; Kinetics

DOI: 10.2967/jnumed.125.271335 · PubMed: 41679918

Cite this article

Zanderigo F, Laurell GL, Doubrovin M, Molotkov A, Ali A, Arevalo RF. Imaging Microtubule Dynamics In Vivo in Human Brain: Optimal Quantification Based on a Test-Retest Study. J Nucl Med. 2026. doi:10.2967/jnumed.125.271335

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Eur J Nucl Med Mol Imaging · Jun 15, 2026 · Research · Radiology & Imaging

Continuous infusion [11C]-(+)-PHNO PET for measuring dopamine D2/3 receptor availability and amphetamine effects across the brain: Feasibility and test-retest reliability

Eur J Nucl Med Mol Imaging · Jan 31, 2026 · Research · Radiology & Imaging

Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolbox

Alzheimers Dement · Oct 31, 2026 · Research · Neurology

CenTauR approach harmonizes tau PET quantification across five tracers

Eur J Nucl Med Mol Imaging · Feb 11, 2026 · Research · Radiology & Imaging

Exploring extended [18F]FDG kinetics in lymphoma with ultra-late LAFOV-PET/CT

Eur J Nucl Med Mol Imaging · Feb 9, 2026 · Research · Radiology & Imaging

Cost-effectiveness of [¹¹C]Choline PET/CT as first-line imaging in primary hyperparathyroidism