ResearchDiabetes Care · Mar 30, 2026

Impact of Missing Data and Monitoring Duration on Downstream Analyses in Continuous Glucose Monitoring

Kok N, Williamson WT, Lee JM, Gaynanova I
Endocrinology & DiabetesAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objective Consensus guidelines recommend at least 14 consecutive days of continuous glucose monitoring (CGM) with 70% completeness to represent 90-day glycemic exposure. This study quantifies bias and uncertainty introduced into downstream analyses by using CGM metrics from incomplete or reduced monitoring, relative to a 90-day complete profile. Research design and methods Using a type 1 diabetes cohort with 1,010 complete 90-day CGM profiles, we simulated incomplete profiles by varying monitoring duration and data completeness. Consensus CGM metrics were computed on incomplete and complete profiles to quantify measurement error, which was propagated into two downstream regression models: 1) CGM metric is an outcome for a binary treatment (clinical trial setting); 2) CGM metric is an explanatory variable (covariate) for another continuous outcome. Bias was quantified using observed-to-true effect size ratios and uncertainty by the sample size increase required to maintain precision. Results In the clinical trial setting, treatment effects remain unbiased but lose precision; for time in range (TIR), 14 days required ≥16% more participants versus 90 days; 30 days required ≥6.5%. When the CGM metric is a covariate, associations with outcomes are attenuated (biased toward zero up to 14% at 14 days and 6% at 30 days for TIR) and less precise. Conclusions Representing 90 days of glycemic exposure with 14 days can lead to bias and loss of precision in downstream analyses. We recommend study protocols require at least 30 days of CGM with 70% completeness. If 30 days is not feasible, studies should plan for increased sample sizes.

Subject terms

Humans; Continuous Glucose Monitoring; Diabetes Mellitus, Type 1; Blood Glucose; Blood Glucose Self-Monitoring

DOI: 10.2337/dc25-2935 · PubMed: 41911328

Headline, design, result, key points, caveat and citation as plain text.

Cite this article

Kok N, Williamson WT, Lee JM, Gaynanova I. Impact of Missing Data and Monitoring Duration on Downstream Analyses in Continuous Glucose Monitoring. Diabetes Care. 2026;49(6):1031-1039. doi:10.2337/dc25-2935

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top Endocrinology & Diabetes studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Similar articles

Review · Diabetes Obes Metab · Jan 27, 2026 · Endocrinology & Diabetes

Rethinking control-IQ+ technology: Simple strategies for easy optimization

Secondary analysis of a trial · Diabetes Care · Sep 3, 2025 · Endocrinology & Diabetes

Continuous glucose monitoring effects on hypoglycemia awareness vary depending on the scoring method used

Review · Diabetologia · Mar 9, 2026 · Endocrinology & Diabetes

Continuous glucose monitoring as a tool in early-stage type 1 diabetes

Research · Diabetes Care · Jul 7, 2026 · Endocrinology & Diabetes

Habituation to Elevated Glucose Levels in Type 1 Diabetes: Function and Well-being in Guideline-Based Versus Typical Glycemic Range

Review · Diabetes Obes Metab · Jan 26, 2026 · Endocrinology & Diabetes

International clinical opinion on transparency, standardisation, and calibration alignment in the performance evaluation of systems for continuous glucose monitoring