Visual abstractsVisuals
ResearchInvestigative Ophthalmology & Visual Science · Apr 15, 2026

Impact of Myopia Control Spectacles on Retinal Image Contrast

Lin Z, Christaras D, Ginis H, Yang Z, Lan W, Artal P
OphthalmologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Purpose Peripheral defocus and image contrast modulation are key strategies in myopia control, but both inherently reduce retinal image contrast. To date, no in vivo study has directly compared these effects. This study evaluated the contrast reduction profiles of different myopia control spectacles to better understand their underlying mechanisms. Methods Through-focus images (TFIs) were obtained with a double-pass instrument in a model eye and in human eyes wearing four spectacle designs: DIMS, Stellest, diffusion optics technology (DOT), and MyoCare. The naked eye served as a reference. Thirteen participants (mean age = 29.0 ± 3.5 years) were tested at the fovea and at 10° and 20° eccentricities in the temporal and superior fields. Lenses were decentered by 1.5 cm to assess off-axis effects. Model eye tests included only the central field. Retinal image contrast (RIC) was calculated as the coefficient of variation of pixel intensity in TFIs. Results In the model eye, RIC ranked from highest to lowest as follows: naked eye, DIMS, DOT, MyoCare, and Stellest. In vivo, DOT results were excluded due to a weak signal. A nonparametric test revealed significant differences in RIC among lenses at the fovea (P = 0.009) and at 10° in the temporal/superior fields (P = 0.05). Post hoc analysis showed that Stellest produced the greatest reduction in RIC, whereas MyoCare and DIMS demonstrated similar levels of contrast loss. Conclusions All myopia control lenses reduced retinal image contrast, with Stellest inducing the strongest reduction. MyoCare and DIMS showed comparable effects. Lens-induced optics primarily influenced contrast in the near periphery, while ocular optics dominated at larger eccentricities.

Topics

Humans; Myopia; Contrast Sensitivity; Adult; Female; Retina; Eyeglasses; Male; Young Adult; Refraction, Ocular; Equipment Design

DOI: 10.1167/iovs.67.4.34 · PubMed: 41983765

Spotted a mistake? Suggest a correction

More in Ophthalmology

Am J Ophthalmol · Nov 20, 2026 · Research · Pediatric · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

JAMA Ophthalmol · Nov 19, 2026 · Randomized trial · Pediatric · Ophthalmology Visual abstract

Higher concentration atropine drops slowed myopia progression in children

Am J Ophthalmol · Nov 19, 2026 · Research · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Ophthalmology · Nov 18, 2026 · Research · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Am J Ophthalmol · Nov 18, 2026 · Research · Ophthalmology

Static perimetry thresholds developed to assess visual field loss severity in retinitis pigmentosa patients