Incremental Prognostic Power of Coronary Flow Reserve and Artificial Intelligence-Enabled ECG-Derived Filling Pressure in Angina With Nonobstructive Coronary Arteries
Study type: Observational study: it can show a link, but not prove that one thing causes another.
Abstract
Background
Coronary flow reserve reflects microvascular function, whereas filling pressure indicates myocardial hemodynamic burden. In angina with nonobstructive coronary arteries, abnormalities in either could contribute to a supply-demand mismatch; however, their combined prognostic significance remains unclear. Methods
Patients with angina with nonobstructive coronary arteries who underwent invasive coronary reactivity tests were studied retrospectively. Coronary microvascular dysfunction (CMD) was coronary flow reserve <2.5. An artificial intelligence-enabled ECG marker of elevated filling pressure (AIEFP) was applied as a scalable prognostic marker of myocardial hemodynamic stress. Associations with major adverse cardiovascular events were evaluated using Cox regression and propensity score overlap weighting. Results
Among 1957 patients with angina with nonobstructive coronary arteries (median age, 51.8 years; 67.2% women), CMD+ was identified in 26.4% and AIEFP+ in 6.6%. Over 8 years, 204 patients (10.4%) experienced major adverse cardiovascular events. In nested models, both CMD (hazard ratio [HR]=1.42 [95% CI=1.13-1.78]; P=0.002) and AIEFP (HR=2.28 [95% CI=1.67-3.11]; P<0.001) remained associated with major adverse cardiovascular events after adjustment. Adding AIEFP to the base model improved model fitness (Δχ2=23.65, P<0.001; ΔAkaike Information Criterion=-21.7) and modestly improved discrimination (ΔHarrell concordance index=0.02, P=0.02). In a 4-group model, adjusted risks increased in a graded manner. Overlap-weighted analysis after covariate balance demonstrated distinct temporal risk trajectories: CMD+/AIEFP+ had the highest 1-year risk (12.7%), and AIEFP+ had the highest cumulative 8-year risk (57% in CMD- and 51.8% in CMD+). Conclusions
CMD and AIEFP provide complementary prognostic information, with AIEFP remaining significantly associated with outcomes after multivariable adjustment. A dual-axis framework integrating myocardial hemodynamic stress (AIEFP) and microvascular function (coronary flow reserve) may enhance risk stratification and enable identification of clinically distinct angina with nonobstructive coronary arteries phenotypes with divergent trajectories.
Subject terms
Headline, design, result, key points, caveat and citation as plain text.
Cite this article
Kalhor P, Manzato M, Hellou E, et al. Incremental Prognostic Power of Coronary Flow Reserve and Artificial Intelligence-Enabled ECG-Derived Filling Pressure in Angina With Nonobstructive Coronary Arteries. J Am Heart Assoc. 2026;15(10):e047946. doi:10.1161/JAHA.125.047946
Spotted a mistake? Suggest a correction