Visual abstractsVisuals
ResearchDiabetes Care · Jan 23, 2026

Interlaboratory Evaluation of Multiplex Autoantibody Assay Performance in the Islet Autoantibody Standardization Program 2024 Workshop

Marzinotto I, Pittman DL, Achenbach P, Akolkar B, Wasserfall CH, Lampasona V, et al
Endocrinology & DiabetesAdult
Read the full paper free at PubMed Central ↗

Abstract

Objective The Islet Autoantibody Standardization Program (IASP) evaluates type 1 diabetes autoantibody assays through international interlaboratory comparison studies. This report describes 2024 IASP workshop results for multiplex assays that simultaneously measure multiple islet autoantibodies, increasingly adopted for population screening programs. Research design and methods Participating laboratories analyzed coded sera from individuals with new-onset type 1 diabetes (n = 50), blood donors with no diabetes (n = 98), and replicate samples (n = 3). Performance was assessed using sensitivity, specificity, adjusted sensitivity at 95%, 99%, and 100% specificity, area under the receiver operating characteristic curve analysis (ROC-AUC), and partial ROC-AUC at 95% specificity (pAUC95). Results Fifteen laboratories contributed results from 19 multiplex assays using five formats: antibody-dependent agglutination PCR (ADAP) (n = 6), bridge-ELISA (n = 8), electrochemiluminescence (n = 2), luciferase immunoprecipitation system (LIPS) (n = 1), and protein A luciferase/solid-phase capture LIPS (n = 2). Median ROC-AUC was 0.98 across all platforms, with a pAUC95 of 0.048 against a theoretical maximum of 0.05. Laboratory-reported sensitivity ranged from 86% to 96% with specificity 81% to 100%. Standardized adjusted sensitivity at 99% specificity thresholds eliminated most false positives without compromising sensitivity, achieving 93-97% adjusted sensitivity. Bridge-ELISA platforms demonstrated potential for universal cutoff standardization, while ADAP showed substantial interlaboratory threshold variation. Conclusions Multiplex assays demonstrated good overall performance for detecting islet autoantibodies and discriminating case subjects from control subjects. However, interlaboratory variability and platform-specific recognition patterns necessitate further standardization efforts. While not directly tested in this workshop, the results suggest that sequential testing strategies using complementary platforms may be necessary to achieve the stringent specificity required when these assays are used in a screening context.

Topics

Humans; Autoantibodies; Diabetes Mellitus, Type 1; Islets of Langerhans; Sensitivity and Specificity; Enzyme-Linked Immunosorbent Assay; ROC Curve

DOI: 10.2337/dc25-1326 · PubMed: 41575380

Spotted a mistake? Suggest a correction

More in Endocrinology & Diabetes

BMJ Open Diabetes Res Care · Nov 19, 2026 · Research · Endocrinology & Diabetes

Hyperglycemia in pregnancy not linked to fetal overgrowth in Malawi study

Thyroid · Nov 18, 2026 · Research · Endocrinology & Diabetes

Combination therapy normalized fT3 levels in simulated hypothyroid patients

Thyroid · Nov 18, 2026 · Research · Endocrinology & Diabetes

Deep learning model predicts lymph node metastasis in thyroid cancer patients

J Endocr Soc · Nov 17, 2026 · Research · Endocrinology & Diabetes

Gluten-free diet had no impact on glycemia or quality of life in type 1 diabetes patients

BMJ Open Diabetes Res Care · Nov 13, 2026 · Research · Endocrinology & Diabetes

DPP4 inhibitors linked to higher angioedema risk than SGLT2 inhibitors