Visual abstractsVisuals
ResearchOphthalmology Science · Feb 18, 2026

Intermediate Term Results of a Novel Minimally Invasive Keratoprosthesis

Sharma J, Dohlman TH, Zhou C, Taniguchi E, Albalakhi A, Somasunder T, et al
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Purpose Keratoprosthesis implantation remains a sight-restoring option in high-risk corneal transplantation where conventional keratoplasty is unlikely to succeed. Existing devices, such as the Boston keratoprosthesis (B-KPro), are very effective but long-term results are limited by glaucoma, infections, retroprosthetic membrane (RPM) formation, and retinal complications. We developed a minimally invasive keratoprosthesis (mi-KPro) that couples an ultrathin nitinol backplate with a poly(methyl methacrylate) optic and is implanted with a modified deep anterior lamellar keratoplasty (DALK) technique. Design An experimental study in rabbits. Subjects Thirty New Zealand white rabbits. Methods Rabbits received severe alkali or acid corneal burns and 1-month later treated with mi-KPro or penetrating keratoplasty (PKP); an additional cohort underwent B-KPro implantation in naïve eyes. Animals were followed for up to 12 months with serial photography, intraocular pressure (IOP) measurements by intracameral manometry and TonoPen, and anterior and posterior segment OCT. Explanted eyes were histologically analyzed. Main outcome measures Endpoints included device anatomic retention, RPM formation, infection, angle status, retinal thickness, and optic nerve axon density on histology. Results The modified DALK approach allowed reproducible mi-KPro implantation with the nitinol backplate seated over Descemet membrane, and the optic extending into the anterior chamber through a 2.5-mm trephination. The mi-KPro eyes maintained clear optics without RPM, haze, or neovascularization and showed stable IOP (15.5 ± 2.2 at last follow-up vs. 15.6 ± 1.5 mmHg at baseline; P = 0.138). In contrast, all PKP grafts failed within 2.2 ± 0.7 months with marked corneal edema, neovascularization, and sustained IOP elevation despite timolol. The B-KPro eyes developed early, refractory IOP rise and staphyloma. Tonopen readings strongly correlated with intracameral IOP (r = 0.95, P = 0.001). OCT and histology demonstrated preservation of angle anatomy, retinal thickness, and optic nerve axons in mi-KPro eyes, whereas PKP eyes exhibited significant retinal thinning (P = 0.0014) and axon loss (P = 0.0001). Conclusions The mi-KPro combines a minimally invasive surgical approach with a flexible nitinol backplate to achieve long-term retention, stable IOP, and preservation of posterior segment structure in severe chemical injury. These data support mi-KPro as a promising next-generation keratoprosthesis for high-risk corneal blindness. Financial disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

DOI: 10.1016/j.xops.2026.101117 · PubMed: 41883733

Cite this article

Sharma J, Dohlman TH, Zhou C, Taniguchi E, Albalakhi A, Somasunder T. Intermediate Term Results of a Novel Minimally Invasive Keratoprosthesis. Ophthalmol Sci. 2026. doi:10.1016/j.xops.2026.101117

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Ophthalmology

Am J Ophthalmol · Nov 20, 2026 · Research · Pediatric · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

JAMA Ophthalmol · Nov 19, 2026 · Randomized trial · Pediatric · Ophthalmology Visual abstract

Higher concentration atropine eye drops slowed myopia progression in children

Am J Ophthalmol · Nov 19, 2026 · Research · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Ophthalmology · Nov 18, 2026 · Research · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Am J Ophthalmol · Nov 18, 2026 · Research · Ophthalmology

Static perimetry thresholds developed to assess visual field loss severity in retinitis pigmentosa patients