Interval breast cancer rates for tomosynthesis vs mammography population screening: a systematic review and meta-analysis of prospective studies
Key result: Digital breast tomosynthesis was associated with lower interval cancer rates compared to digital mammography
Key points
- Researchers analyzed ten prospective studies involving 205,245 participants screened with digital breast tomosynthesis and 306,476 participants screened with digital mammography.
- The pooled absolute interval cancer rate did not significantly differ between the two methods with a difference of -2.92 per 10,000 screens (95% CI: -6.39 to 0.54).
- In a subgroup analysis of studies sampling groups from the same time and region, digital breast tomosynthesis was associated with 5.50 fewer interval cancers per 10,000 screens (95% CI: -9.47 to -1.54).
Limitation the authors note: Subgroup analysis indicated certain study designs may have biased the interval cancer rate estimate.
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: Libesman S, Li T, Marinovich ML, Seidler AL, Tagliafico AS, Houssami N. Interval breast cancer rates for tomosynthesis vs mammography population screening: a systematic review and meta-analysis of prospective studies. Eur Radiol. 2025;35(3):1478-1489. doi:10.1007/s00330-024-11085-9
Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/interval-breast-cancer-rates-for-tomosynthesis-vs-mammography-xpj96r/ (AI-assisted from the abstract; check the paper before relying on it).