ResearchBrain & Spine · Aug 18, 2026

Intraoperative cone-beam CT for real-time quality control in CSF shunt surgery: a prospective workflow study

Qasem LE, Karakaya D, Seemann C, Döpke NA, Mann L, Keil F, et al
NeurosurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Introduction Postoperative CT is routinely performed after cerebrospinal fluid (CSF) shunt implantation to verify catheter position. Intraoperative cone-beam CT (iCBCT) enables real-time verification and may obviate routine postoperative CT. Research question Does an iCBCT-based workflow reduce radiation exposure and permit omission of routine postoperative CT? Methods This interim analysis of an ongoing, prospective, observational study enrolled 10 patients undergoing ventriculoperitoneal (VP), lumboperitoneal (LP), ventriculoatrial (VA), or cyst shunt implantation with iCBCT-based quality control and compared them with a matched retrospective cohort of 10 patients managed by conventional postoperative CT. The primary endpoint was radiation exposure. Secondary endpoints were operative duration and the number of immediate revisions for catheter malposition. Results The volumetric dose index was lower in the iCBCT group than in the control group (CBDIw median 9.27 mGy [IQR, 6.5-11.5] vs CTDIvol 31.15 mGy [IQR, 23.5-34.2]; p = 0.002). Intraoperative imaging detected catheter malposition in one VP shunt and enabled immediate revision within the same surgical session. Routine postoperative CT was omitted in all iCBCT patients, without catheter-related complications through the routine 2-3-week postoperative follow-up. OR time was longer in the iCBCT group due to image acquisition without statistical significance (median 142 min [IQR, 114-157] vs 127 min [IQR, 104-140]; p = 0.2948). Surgical time was comparable between groups (median 65.5 min [IQR, 54-80] vs 60 min [IQR, 50-76]; p = 0.590). Discussion and conclusion In this interim cohort, iCBCT lowered the radiation dose index and replaced postoperative CT, enabling real-time catheter verification across CSF shunts.

DOI: 10.1016/j.bas.2026.106269 · PubMed: 42662521

Cite this article

Qasem LE, Karakaya D, Seemann C, Döpke NA, Mann L, Keil F. Intraoperative cone-beam CT for real-time quality control in CSF shunt surgery: a prospective workflow study. Brain Spine. 2026. doi:10.1016/j.bas.2026.106269

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

More in Neurosurgery

Research · Cancer Commun · Nov 18, 2026 · Oncology, Neurosurgery

SLC38A2 promotes hypoxic survival in glioblastoma through glutamine metabolic reprogramming

Research · Neuro Oncol · Nov 14, 2026 · Neurosurgery

AI was linked to improved tumor quantification and response assessment in neuro-oncology

Review · Brain Spine · Nov 13, 2026 · Neurosurgery

Social disadvantage and metabolic factors are linked to idiopathic intracranial hypertension in women

Research · Brain Spine · Nov 13, 2026 · Neurosurgery

Endoscopic endonasal approach was linked to symptom improvement in Rathke's cleft cysts

Research · Brain Spine · Nov 13, 2026 · Neurosurgery

Endoscopic foraminoplasty was associated with long-term restoration of cerebrospinal fluid flow in seven patients