Indocyanine green fluorescence angiography was associated with lower odds of free flap failure and reoperation
Intraoperative indocyanine green versus clinical assessment for prevention of free flap failure: A systematic review and meta-analysis
Clinical question: Does intraoperative indocyanine green fluorescence angiography prevent free flap failure compared to clinical assessment?
Why it matters: It is unclear if using indocyanine green fluorescence angiography during surgery differs from standard clinical assessment in preventing total or partial flap loss.
- Researchers analyzed eight studies involving 2179 free-tissue transfer procedures, comparing indocyanine green fluorescence angiography—a specialized imaging technique—to standard clinical assessment.
- The use of indocyanine green fluorescence angiography was associated with a 90% reduction in odds for partial flap failure (OR 0.10, 95% CI: 0.04, 0.26; p < 0.01).
- The imaging technique was also associated with a 41% reduction in odds for total flap failure (OR 0.59, 95% CI: 0.35, 0.97; p = 0.04) and a 53% reduction in reoperation requirements (OR 0.47, 95% CI: 0.25, 0.88; p = 0.02).
Limitation the authors note: Further high-quality prospective trials are required to clarify the true magnitude of effect and its role in microsurgical practice.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.