Visual abstractsVisuals
ResearchJournal of Cardiovascular Magnetic Resonance · Jan 23, 2026

Isotropic three-dimensional cardiac cine imaging at 0.55T using stack-of-spiral sampling and four-dimensional iterative motion compensation

Ramasawmy R, Javed A, Herzka DA, Kumar P, Nayak KS, Lederman RJ, et al
Radiology & ImagingAdult
Read the full paper free at PubMed Central ↗

Abstract

Background Isotropic three-dimensional (3D) cine imaging is an attractive one-stop-shop acquisition for cardiac MRI, as it can be arbitrarily resliced for the assessment of cardiac function and simplifies imaging workflows. Current free-breathing 3D cine approaches are hampered by long reconstruction times, and at lower-field strengths, by relatively long acquisition times. Here, we aim to maximize acquisition efficiency at 0.55T pairing two techniques; using a spiral acquisition with an optimized sampling distribution and a reconstruction incorporating data from all respiratory phases. Methods We implemented a 2 mm isotropic 3D cine approach on a prototype 0.55T scanner, using a 6 min stack-of-spiral balanced steady-state free precession (bSSFP) acquisition modified to use tiny-golden-angle in-plane rotations and distribute the kz partition samples to a variable-density. The data were reconstructed with a modified iterative motion compensation reconstruction which resolved cardiac motion (denoted 4D iMoCo) and combined respiratory states using a navigator signal extracted from the acquired data. The proposed technique was compared to reference 2D free-breathing Cartesian volumetry of the left ventricle in 11 human subjects. Results The 4D iMoCo reconstruction required 20 min. The proposed variable-density sampling distribution reduced image artifacts, compared to a common linear sampling approach, and improved apparent signal-to-noise with relative increase of 221 ± 99%. Measurements had good agreement with the 2D Cartesian reference data with a left-ventricular volume bias of -2.5 ± 6.2% and 2.6 ± 10.4% in diastole and systole, respectively, and an ejection fraction bias of -3.5 ± 8.8%. Conclusion We demonstrate an efficient free-breathing technique to produce 2 mm isotropic 3D cardiac images within a 6 min acquisition time and 20 min reconstruction time at 0.55T. Such a method could be a valuable clinical tool for cardiac imaging.

Topics

Humans; Magnetic Resonance Imaging, Cine; Imaging, Three-Dimensional; Predictive Value of Tests; Image Interpretation, Computer-Assisted; Reproducibility of Results; Female; Respiration; Male; Time Factors; Ventricular Function, Left; Adult

DOI: 10.1016/j.jocmr.2026.102698 · PubMed: 41581732

Cite this article

Ramasawmy R, Javed A, Herzka DA, Kumar P, Nayak KS, Lederman RJ. Isotropic three-dimensional cardiac cine imaging at 0.55T using stack-of-spiral sampling and four-dimensional iterative motion compensation. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102698

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Cardiovasc Magn Reson · Feb 17, 2026 · Research · Basic science · Radiology & Imaging, Digital Health & AI

Open-source pre-clinical image segmentation: mouse cardiac magnetic resonance imaging datasets with a deep learning segmentation framework

J Cardiovasc Magn Reson · Dec 24, 2025 · Research · Radiology & Imaging, Cardiology

Cardiac function assessment with deep-learning-based automatic segmentation of free-running four-dimensional whole-heart cardiovascular magnetic resonance

J Cardiovasc Magn Reson · Dec 24, 2025 · Research · Radiology & Imaging, Cardiology

Free-breathing three-dimensional whole-heart adiabatic T1ρ mapping for non-contrast tissue characterization at 0.55T

J Cardiovasc Magn Reson · Dec 17, 2025 · Research · Pediatric · Radiology & Imaging, Cardiology

Automatic respiratory and bulk patient motion corrected (ACROBATIC) free-running whole-heart five-dimensional magnetic resonance imaging

J Cardiovasc Magn Reson · Dec 12, 2025 · Research · Radiology & Imaging, Cardiology

Comprehensive three-dimensional free-breathing magnetic resonance imaging for simultaneous myocardial viability and coronary artery visualization at 1.5T and 3T