Randomized trialJAMA Cardiology · Jul 31, 2024

Leadless Ultrasound-Based Cardiac Resynchronization System in Heart Failure

Singh JP, Rinaldi CA, Sanders P, Kubo SH, James S, Niazi IK, et al
CardiologyAdult
Read the full paper free at PubMed Central ↗

Abstract

Importance Approximately 40% of patients with heart failure (HF) who are eligible for cardiac resynchronization therapy (CRT) either fail to respond or are untreatable due to anatomical constraints. Objective To assess the safety and efficacy of a novel, leadless, left ventricular (LV) endocardial pacing system for patients at high risk for a CRT upgrade or whose coronary sinus (CS) lead placement/pacing with a conventional CRT system failed. Design, setting, and participants The SOLVE-CRT study was a prospective multicenter trial enrolling January 2018 through July 2022, with follow-up at 6 months. Data were analyzed from January 17, 2018, through February 15, 2023. The trial combined data from an initial randomized, double-blind study (n = 108) and a subsequent single-arm part (n = 75). It took place at 36 centers across Australia, Europe, and the US. Participants were nonresponders, previously untreatable (PU), or high-risk upgrades (HRU). All participants contributed to the safety analysis. The primary efficacy analysis (n = 100) included 75 PU-HRU patients from the single-arm part and 25 PU-HRU patients from the randomized treatment arm. Interventions Patients were implanted with the WiSE CRT System (EBR Systems) consisting of a leadless LV endocardial pacing electrode stimulated with ultrasound energy delivered by a subcutaneously implanted transmitter and battery. Main outcomes and measures The primary safety end point was freedom from type I complications. The primary efficacy end point was a reduction in mean LV end systolic volume (LVESV). Results The study included 183 participants; mean age was 68.1 (SD, 10.3) years and 141 were male (77%). The trial was terminated at an interim analysis for meeting prespecified stopping criteria. In the safety population, patients were either New York Heart Association Class II (34.6%) or III (65.4%). The primary efficacy end point was met with a 16.4% (95% CI, -21.0% to -11.7%) reduction in mean LVESV (P = .003). The primary safety end point was met with an 80.9% rate of freedom from type I complications (P < .001), which included 12 study device system events (6.6%), 5 vascular events (2.7%), 3 strokes (1.6%), and 7 cardiac perforations which mostly occurred early in the study (3.8%). Conclusions and relevance The SOLVE-CRT study has demonstrated that leadless LV endocardial pacing with the WiSE CRT system is associated with a reduction in LVESV in patients with HF. This novel system may represent an alternative to conventional CRT implants in some HF patient populations. Trial registration ClinicalTrials.gov Identifier: NCT0292203.

Topics

Aged; Female; Humans; Male; Middle Aged; Cardiac Resynchronization Therapy; Cardiac Resynchronization Therapy Devices; Double-Blind Method; Heart Failure; Prospective Studies; Treatment Outcome

DOI: 10.1001/jamacardio.2024.2050 · PubMed: 39083254

Cite this article

Singh JP, Rinaldi CA, Sanders P, Kubo SH, James S, Niazi IK. Leadless Ultrasound-Based Cardiac Resynchronization System in Heart Failure. JAMA Cardiol. 2024. doi:10.1001/jamacardio.2024.2050

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

Review · NEJM · Jan 21, 2026 · Cardiology

Physiologic Pacing in Heart Failure

Randomized trial · Cardiovasc Diabetol · Nov 28, 2020 · Cardiology, Endocrinology & Diabetes

Cardiac resynchronization therapy and its effects in patients with type 2 DIAbetes mellitus OPTimized in automatic vs. echo guided approach. Data from the DIA-OPTA investigators

Randomized trial · Circulation · Mar 30, 2026 · Cardiology

Two-lead cardiac resynchronization therapy was not inferior to three-lead therapy for patient outcomes

Review · JAMA · Apr 27, 2026 · Cardiology

Cardiac Resynchronization Therapy: A Review

Guideline · Eur J Heart Fail · Apr 9, 2025 · Cardiology

Expert consensus review discusses the role and timing of cardiac rhythm devices in heart failure