Long-term Follow-up After Hypothermic Oxygenated Machine Perfusion in DCD Liver Transplantation: Results of a Randomized Controlled Multicenter Trial (DHOPE-DCD)
Key result: Machine perfusion of livers from circulatory death donors was linked to fewer long-term biliary strictures
Key points
- Researchers studied 78 patients receiving livers via dual hypothermic oxygenated machine perfusion and 78 patients receiving livers via conventional static cold storage.
- At 5-year follow-up, the incidence of nonanastomotic biliary strictures was 14% in the machine perfusion group compared to 26% in the control group.
- In patients with immune-mediated disease, the rate of acute cellular rejection was 0% in the machine perfusion group versus 32% in the control group.
Discussion prompts
- Would these patients look like yours? Who was left out?
- Is the main outcome one that matters to patients?
- Is the difference large enough to change what you do?
Cite: van Rijn R, Endo C, Küçükerbil EH, et al. Long-term Follow-up After Hypothermic Oxygenated Machine Perfusion in DCD Liver Transplantation: Results of a Randomized Controlled Multicenter Trial (DHOPE-DCD). Ann Surg. 2025;282(5):717-724. doi:10.1097/SLA.0000000000006876
Free full text: PubMed Central · Summary and visual abstract: nowallmed.com/a/long-term-follow-up-after-hypothermic-oxygenated-machine-perfusion-in-gfyq4z/ (AI-assisted from the abstract; check the paper before relying on it).