Low-dose, high-frequency simulation with respiratory function monitor feedback enhances face mask ventilation across neonatal resuscitation devices: A prospective study in neonatology fellows

Carlton SJ, Hagan JL, Neveln NK, Lemke DS, Sundgren NC
Emergency MedicinePediatricsPediatric

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Face mask ventilation (FMV) is a critical skill in neonatal resuscitation, yet structured assessment of neonatology fellow competence has remained limited. This study evaluated whether low-dose, high-frequency simulation with real-time respiratory function monitor (RFM) feedback improved FMV performance across commonly used ventilation devices. A prospective, single-center study was conducted over nine months involving neonatology fellows who performed simulated FMV using a T-piece resuscitator, self-inflating bag, and flow-inflating bag. Each session included blinded and unblinded RFM conditions. Primary outcomes included tidal volume (TV) within target range, mask leak, peak inspiratory pressure (PIP), positive end-expiratory pressure (PEEP), respiratory rate, and self-reported proficiency. Mixed-effects models accounted for repeated measures. TV within goal range was higher with RFM feedback (80.3% vs 62.3%, p < 0.0001) and mask leak was lower with feedback across all three devices. No independent effect of feedback was observed for PIP or respiratory rate. Increasing session number improved respiratory rate, PIP, and PEEP but did not significantly improve TV or mask leak, suggesting limited skill improvement without feedback. Performance varied by device modestly, but higher performance was associated with RFM feedback and practice sessions across all devices. Self-reported confidence improved significantly across all devices, though clinical FMV frequency did not change. These findings support the use of RFMs in neonatal training regardless of device type while highlighting the need for strategies to improve long-term skill retention.

DOI: 10.1016/j.resplu.2026.101497 · PubMed: 42835672

Cite this article

Carlton SJ, Hagan JL, Neveln NK, Lemke DS, Sundgren NC. Low-dose, high-frequency simulation with respiratory function monitor feedback enhances face mask ventilation across neonatal resuscitation devices: A prospective study in neonatology fellows. Resusc Plus. 2026. doi:10.1016/j.resplu.2026.101497

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Emergency Medicine

J Med Internet Res · Nov 23, 2026 · Meta-analysis · Digital Health & AI, Emergency Medicine

Large language models mainly used for documentation in emergency departments

BMJ Med · Nov 18, 2026 · Research · Emergency Medicine

Direct admission to level 1 trauma centre was linked to lower 30 day mortality

Am J Emerg Med · Nov 13, 2026 · Research · Emergency Medicine, Hematology

ED red blood cell transfusion linked to longer hospital stays in severe anemia

J Med Internet Res · Nov 13, 2026 · Research · Digital Health & AI, Emergency Medicine

Physicians often intend to act on false information in AI-generated abstracts

Am J Emerg Med · Nov 12, 2026 · Research · Emergency Medicine, Neurology

Serum lactate levels differed across neurologic emergencies in emergency patients