Visual abstractsVisuals
ResearchOphthalmology Science · May 25, 2026

Macular Layer Thickness with Spectral-Domain and High-Resolution OCT

Baek SU, Sharpe GP, Shuba LM, Nicolela MT, Chauhan BC
OphthalmologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Objective The new generation high-resolution OCT (HR-OCT) offers higher axial resolution compared to standard spectral-domain OCT (SD-OCT). This study aimed to determine whether potential differences in the segmentation of retinal layers in the macula with the 2 techniques could lead to clinically meaningful differences with implications for monitoring progression when patients are switched to HR-OCT. Design Prospective cross-sectional study. Subjects This study included glaucoma patients and healthy control subjects. Methods Each eye underwent SD-OCT followed by HR-OCT, with both macular scan patterns acquired at the same transverse location. Automated segmentation was applied and the thickness of 6 individual retinal layers calculated for 1024 A-scans for each of 97 B-scans. Intradevice difference was also assessed with repeated scans. Main outcome measures Differences in retinal layer thickness measurements between SD-OCT and HR-OCT. Results A total of 68 eyes (both eyes of 17 glaucoma patients and 17 healthy control subjects) underwent imaging. Mean differences in retinal layer thickness between SD-OCT and HR-OCT ranged from -2.65 to 2.02 μm. Hyper-reflective layers were thicker with SD-OCT, while hyporeflective layers were thicker with HR-OCT, showing an alternating pattern in interdevice differences in thickness measurements. Intradevice differences in thickness measurements, evaluated in a subset of 10 eyes of 5 participants, were within ± 1 μm. Image quality was not an important predictor of the interdevice thickness differences (R2 Conclusions Interdevice differences in retinal layer thickness were small but consistent. The alternating pattern is likely due to the lower axial resolution of SD-OCT making hyper-reflective layer borders blurred and consequently thicker. For follow-up, patients can be switched to HR-OCT from SD-OCT; however, depending on the magnitude of change required for detection, the differences between the 2 techniques could potentially mask or masquerade change. Financial disclosures Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

DOI: 10.1016/j.xops.2026.101251 · PubMed: 42437117

Spotted a mistake? Suggest a correction

More in Ophthalmology

ResearchPediatricAm J Ophthalmol · Nov 20, 2026 · Ophthalmology

Allergic conjunctivitis severity linked to meibomian gland loss in children

Association of allergic conjunctivitis severity with meibomian gland abnormalities in children: a cross-sectional study

Randomized trialVisual abstractPediatricJAMA Ophthalmol · Nov 19, 2026 · Ophthalmology

Higher concentration atropine drops slowed myopia progression in children

Low-Concentration Atropine Eye Drops in Children With Myopia and Intermittent Exotropia: The AMIXT2 Randomized Clinical Trial

ResearchAm J Ophthalmol · Nov 19, 2026 · Ophthalmology

Wildfire smoke exposure linked to Leber's Hereditary Optic Neuropathy conversion

Smoke, Not Smoking, as a Possible Risk Factor Triggering Conversion in Leber's Hereditary Optic Neuropathy: A Retrospective Case Series

ResearchOphthalmology · Nov 18, 2026 · Ophthalmology

Enucleations decreased and globe-sparing radiation increased for uveal melanoma

Trends and Variation in Uveal Melanoma Management in the National Cancer Database, 2004-2023

ResearchAm J Ophthalmol · Nov 18, 2026 · Ophthalmology

Static perimetry thresholds correlate with kinetic perimetry in retinitis pigmentosa patients

Developing Static Perimetry Thresholds to Assess Visual Field Loss Severity in Patients with Retinitis Pigmentosa