Mechanical ventilation was not found to be noninferior to bag-valve ventilation for tidal volume during resuscitation
Mechanical ventilation vs bag-valve ventilation during cardiopulmonary resuscitation: a randomized crossover noninferiority trial
Clinical question: Is mechanical ventilation noninferior to bag-valve ventilation for inspired tidal volume during resuscitation?
Why it matters: Evidence is limited regarding whether mechanical ventilation or bag-valve ventilation provides more consistent inspired tidal volumes during cardiopulmonary resuscitation.
- Researchers studied 99 intubated adults who did not regain spontaneous circulation to compare inspired tidal volume using mechanical ventilation versus bag-valve ventilation.
- The adjusted mean difference in median tidal volume was -146.2 mL, but noninferiority was not demonstrated because the lower bound crossed the -150 mL margin.
- Mechanical ventilation produced lower and less variable tidal volumes, with 45.5% of participants receiving values below 6 mL/kg compared to 26.3% with bag-valve ventilation.
Limitation the authors note: The study used an unvalidated analyzer and did not measure clinical outcomes.
Headline and key points written with AI from the paper’s abstract, with every number checked against it. Read the paper before relying on them.
Cite this article
Vinay S, Manu Ayyan S, Amrithanand VT, Kowsthubha BG. Mechanical ventilation vs bag-valve ventilation during cardiopulmonary resuscitation: a randomized crossover noninferiority trial. Resusc Plus. 2026. doi:10.1016/j.resplu.2026.101530
Spotted a mistake? Suggest a correction