Metric discordance under MIDOG++ domain shift: a leave-one-domain-out audit of F1, emitted-detection confidence calibration, and ROI count error

de Souza C
Pathology & Laboratory MedicineAdult
Read the full paper free at PubMed Central ↗
Top Pathology & Laboratory Medicine studies every Monday

The week’s key trials and guidelines, free to read, in one short email. No account; unsubscribe in one click.

Choose specialties and topics

Abstract

Background Mitotic-figure detectors are usually evaluated by detection accuracy, but use also depends on confidence and count reliability under domain shift. Methods We evaluated MIDOG++ with leave-one-domain-out testing across seven domains. Adaptive-bin detection expected calibration error (D-ECE1) measured the bin-mass-weighted mean absolute confidence-precision gap among post-non-maximum suppression detections retained at a 0.05 score floor; centroid-distance matching supplied the true positive/false positive labels. F1 and count error were evaluated at the fixed 0.5 operating threshold. Baseline and domain-adversarial RetinaNet arms were compared as a controlled perturbation, with exploratory domain-composition resampling and two secondary seeds. Results No directionally stable aggregate calibration advantage was established across three seed series. In the primary series, macro D-ECE1 was 0.0786 for baseline and 0.0741 for the domain-adversarial arm (paired difference, -0.0045), but two additional seed series produced paired differences of +0.0287 and -0.0068. A provenance audit confirmed the secondary series were generated under the locked protocol; they were reported as a sensitivity comparison and were not pooled with the primary point estimate. The fixed-domain case-bootstrap interval was below zero, whereas exploratory domain-composition resampling crossed zero (-0.0213 to +0.0112). The two domains with F1 gains had worse D-ECE1. Lymphoma/lymphosarcoma had the highest observed D-ECE1 in both arms and was systematically undercounted. Conclusions In this benchmark, F1, emitted-detection calibration, count behavior, and maximum observed-domain D-ECE1 were not interchangeable endpoints. The tested domain-adversarial configuration did not establish a directionally stable calibration benefit. Evaluations should report detection-specific calibration, retained-detection denominators, count consequences, and finite-benchmark observed-domain D-ECE1 alongside F1.

DOI: 10.1016/j.jpi.2026.100705 · PubMed: 42668538

Cite this article

de Souza C. Metric discordance under MIDOG++ domain shift: a leave-one-domain-out audit of F1, emitted-detection confidence calibration, and ROI count error. J Pathol Inform. 2026. doi:10.1016/j.jpi.2026.100705

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Pathology & Laboratory Medicine

Research · Alzheimers Dement · Nov 19, 2026 · Neurology, Pathology & Laboratory Medicine

Mixed neuropathology was common in Alzheimer's disease and related dementias

Research · Mod Pathol · Nov 18, 2026 · Pathology & Laboratory Medicine

Tumor-selective overexpression of five receptors found in triple-negative breast cancer

Research · Mod Pathol · Nov 18, 2026 · Pathology & Laboratory Medicine, Oncology

CD40 expression differentiates Hodgkin lymphoma from anaplastic large cell lymphoma

Research · Diagn Pathol · Nov 18, 2026 · Pathology & Laboratory Medicine, Oncology

Claudin-1 and Claudin-4 proteins are expressed in penile squamous cell carcinoma tumors

Research · J Pathol Clin Res · Nov 16, 2026 · Pathology & Laboratory Medicine, Oncology

Surgical resection and biopsy are associated with different molecular profiles in liver cancer tissue