Visual abstractsVisuals
ResearchJournal of Thoracic and Cardiovascular Surgery · Feb 26, 2026

Microinvasive, off-pump, transventricular neochordae implantation in recurrent mitral valve regurgitation after open heart surgical repair

Salizzoni S, Yadav R, Sardari Nia P, Adams C, Mastro F, Barbero C, et al
Cardiothoracic & Vascular SurgeryAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at the publisher ↗

Abstract

Objective Mitral valve repair (MVr) is the standard treatment for degenerative mitral regurgitation (MR). However, MR may recur, and reoperation is associated with increased mortality and technical complexity. Microinvasive MVr using the NeoChord technique in redo setting is performed off-pump, offering clear advantages, particularly in high-risk patients. Methods This retrospective, multicenter, international registry included 92 patients treated with the NeoChord technique between 2014 and 2025 for recurrent MR after previous MVr across 32 centers. The primary composite end point was freedom from recurrence of severe MR, need for reintervention due to technical failure, and 30-day or cardiovascular mortality. Results Neochord repair was successful in 91 patients (98.9%); one was converted to open surgery. Mean age was 64.6 ± 11.6; 22 patients (23.9%) were female. Mean left ventricle ejection fraction was 57.4 ± 8.1%; European System for Cardiac Operative Risk Evaluation was 4.3 ± 3.2%. A median of 3 chords was implanted. Mean procedural time was 139 ± 65 minutes. At discharge, MR was mild or less in 93.5%. One patient (1.1%) died on day 8. One life-threatening bleeding and one acute myocardial infarction were reported. Median hospital length-of-stay was 5 days; 47.8% of patients were extubated in the operating room. The primary end point was achieved in 81.3 ± 6.6% of patients at 5 years (Kaplan-Meier analysis). Seven patients (8.6%) underwent re-reintervention; 3 remained with severe MR. In the multivariate analysis, older age was associated with an increased risk (hazard ratio, 1.160; 95% CI, 1.021-1.317), whereas greater hemoglobin levels were protective (hazard ratio, 0.423; 95% CI, 0.233-0.768). Conclusions Microinvasive NeoChord repair provides excellent procedural and 5-year outcomes with very low mortality, supporting its role as a valuable option for reoperative mitral valve surgery.

Topics

Humans; Female; Mitral Valve Insufficiency; Middle Aged; Retrospective Studies; Male; Aged; Recurrence; Reoperation; Registries; Mitral Valve; Heart Valve Prosthesis Implantation

DOI: 10.1016/j.jtcvs.2026.01.036 · PubMed: 41763387

Cite this article

Salizzoni S, Yadav R, Sardari Nia P, Adams C, Mastro F, Barbero C. Microinvasive, off-pump, transventricular neochordae implantation in recurrent mitral valve regurgitation after open heart surgical repair. J Thorac Cardiovasc Surg. 2026. doi:10.1016/j.jtcvs.2026.01.036

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Similar articles

J Thorac Cardiovasc Surg · Mar 23, 2026 · Research · Cardiothoracic & Vascular Surgery

Impact of reoperation on very long-term survival in patients with failed mitral valve repair: A 30-year single-center Canadian experience

J Thorac Cardiovasc Surg · Jun 3, 2026 · Research · Cardiothoracic & Vascular Surgery

Impact and outcomes of failure mode after mitral valve repair

J Thorac Cardiovasc Surg · Jul 6, 2026 · Research · Cardiothoracic & Vascular Surgery

Pushing the age limit: Mitral valve surgery is safe and effective in octogenarians

J Am Heart Assoc · Aug 27, 2026 · Research · Cardiology

Transcatheter Edge-to-Edge Repair With MitraClip G4 System Compared With PASCAL System in Patients With Functional Mitral Regurgitation: A Propensity Score-Matched Analysis

J Am Heart Assoc · Dec 10, 2025 · Research · Cardiology

Safety and Prognostic Implications of Mechanical Circulatory Support-Assisted Transcatheter Edge-to-Edge Repair: The OCEAN-Mitral Registry