Visual abstractsVisuals
ResearchJournal of Allergy and Clinical Immunology: Global · Jul 23, 2026

Microneedles for allergy skin testing: Comprehensive analysis of agreement, accuracy, and pain

Sirichuwong M, Kanchanapoomi K, Piboonpocanun S, Srisuwatchari W, Pacharn P, Rayanasukha Y, et al
Allergy & ImmunologyPediatric
Read the full paper free at PubMed Central ↗

Abstract

Background The skin prick test (SPT) is a standard method for identifying allergic sensitization. However, pain and needle phobia often compromise pediatric compliance. Microneedle devices offer a minimally invasive alternative to conventional lancets. Objective We evaluated the agreement, diagnostic accuracy, and patient tolerability of a novel microneedle compared to a lancet for SPT. Methods Subjects with allergic rhinitis underwent SPT using both devices with Dermatophagoides pteronyssinus (Dp) extract, histamine, and saline controls. Net mean wheal diameters (MWD) were calculated by subtracting the saline MWD from the Dp and histamine MWDs. Agreement was assessed by Bland-Altman analysis and Cohen kappa (k), diagnostic performance by receiver operating characteristic analysis, and pain by a visual analog scale. Results Of 150 subjects (aged 8-60 years), 53.3% were sensitized to Dp. Both devices produced significantly larger Dp and histamine MWDs than saline MWD (P < .001). Median [interquartile range] Dp MWD was smaller with microneedle (2 [0-8.13] mm) than lancet (4 [0-12.5 mm], P < .001). For net Dp MWD, Bland-Altman analysis indicated a mean bias of -2.1 mm for microneedle, with 93.3% within the limits of agreement. With lancet used as the reference, the microneedle had an area under the curve of 0.904. At a 3 mm cutoff, sensitivity was 82.5%, specificity 94.3%, and accuracy 86%. Interdevice concordance was good (k = 0.76). Median pain scores were significantly lower for microneedle (2.5 [0-9]) compared to lancet (8.0 [1-26], P < .001). Conclusion The microneedle demonstrates high diagnostic performance and good concordance with the standard lancet while significantly reducing pain, thus supporting its utility in pediatric and needle-averse populations.

DOI: 10.1016/j.jacig.2026.100765 · PubMed: 42621047

Cite this article

Sirichuwong M, Kanchanapoomi K, Piboonpocanun S, Srisuwatchari W, Pacharn P, Rayanasukha Y. Microneedles for allergy skin testing: Comprehensive analysis of agreement, accuracy, and pain. JACI Glob. 2026. doi:10.1016/j.jacig.2026.100765

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

More in Allergy & Immunology

J Allergy Clin Immunol Pract · Nov 22, 2026 · Meta-analysis · Allergy & Immunology

Adding tumor necrosis factor inhibition to corticosteroids may control disease earlier

J Allergy Clin Immunol Pract · Nov 21, 2026 · Meta-analysis · Allergy & Immunology Visual abstract

Twice-daily and once-daily intranasal therapy showed similar efficacy and safety

JACI · Nov 20, 2026 · Research · Allergy & Immunology

Non-immune features persisted in 98 percent of patients despite metabolic detoxification

JACI · Nov 19, 2026 · Review · Allergy & Immunology

Molecular information may improve diagnosis and treatment of inflammatory skin diseases

JACI · Nov 18, 2026 · Research · Allergy & Immunology

Asplenia found in 17-20% of patients with autoimmune polyendocrinopathy-candidiasis-ectodermal dystrophy