ResearchBrain & Spine · Feb 26, 2026

Minimally invasive cervical spine stabilization: A multicenter study of completely percutaneous pedicle screw-rod instrumentation

Klingler JH, Wessels L, Scholz C, Schmidt TP, Bertram U, Hohenhaus M, et al
NeurosurgeryOrthopedics & Sports MedicineObstetrics & GynecologyAdult

Study type: Observational study: it can show a link, but not prove that one thing causes another.

Read the full paper free at PubMed Central ↗

Abstract

Introduction Minimally invasive posterior cervical fixation remains technically challenging due to narrow pedicle dimensions and proximity to neurovascular structures. This multicenter study evaluates the accuracy and safety of a dedicated minimally invasive cervical pedicle screw-rod system with 3D navigation guidance. Research question Can minimally invasive cervical pedicle screw placement achieve accuracy rates comparable to open techniques while maintaining patient safety? Material and methods Retrospective multicenter analysis of 46 patients (60.7 ± 17.4 years) undergoing percutaneous cervical pedicle screw-rod instrumentation at three German university centers (01/2022-04/2024). Indications included degenerative disease (n = 21), tumors (n = 13), trauma (n = 8), and inflammation (n = 4). Primary outcome was neurological status (Frankel classification); secondary outcomes included screw accuracy (Bredow classification), surgical characteristics, and complications. All procedures utilized 3D navigation based on cone-beam CT or intraoperative CT. Results In total, 232 pedicle screws were implanted from C2 to T2. Favorable screw position (Bredow grades 1-2) was achieved in 89.7% overall, with significantly lower accuracy at C3-C6 versus other levels (86.0% vs. 95.4%, p = 0.0297). No permanent neurological deficits occurred. Two screws required intraoperative repositioning; zero revision surgeries were needed. Mean surgical duration was 148 ± 66min with blood loss of 236 ± 183 ml. Discussion and conclusion Minimally invasive cervical pedicle screw-rod instrumentation with 3D navigation achieves high accuracy and safety comparable to open techniques. In the majority of cases, the technique supplemented anterior fusion for additional stability, but it may also serve as posterior-only instrumentation for in tumor-related osteolysis or traumatic injuries. Mid-cervical levels remain particularly challenging and require heightened vigilance.

DOI: 10.1016/j.bas.2026.105996 · PubMed: 41799387

Cite this article

Klingler JH, Wessels L, Scholz C, Schmidt TP, Bertram U, Hohenhaus M. Minimally invasive cervical spine stabilization: A multicenter study of completely percutaneous pedicle screw-rod instrumentation. Brain Spine. 2026. doi:10.1016/j.bas.2026.105996

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, by email. Free.

Get the weekly digest

More in Neurosurgery

Research · Cancer Commun · Nov 18, 2026 · Oncology, Neurosurgery

SLC38A2 promotes hypoxic survival in glioblastoma through glutamine metabolic reprogramming

Research · Neuro Oncol · Nov 14, 2026 · Neurosurgery

AI was linked to improved tumor quantification and response assessment in neuro-oncology

Review · Brain Spine · Nov 13, 2026 · Neurosurgery

Social disadvantage and metabolic factors are linked to idiopathic intracranial hypertension in women

Research · Brain Spine · Nov 13, 2026 · Neurosurgery

Endoscopic endonasal approach was linked to symptom improvement in Rathke's cleft cysts

Research · Brain Spine · Nov 13, 2026 · Neurosurgery

Endoscopic foraminoplasty was associated with long-term restoration of cerebrospinal fluid flow in seven patients