Background
A cardiac computed tomography (CT)-based mitral annular calcification (MAC) scoring system systematically grades MAC severity, but its correlation with three-dimensional transesophageal echocardiography (3D-TEE) remains unclear. Objectives
The authors aimed to compare MAC severity assessment by 3D-TEE vs CT and evaluate their associations with hemodynamic parameters indicative of mitral valve disease. Methods
We analyzed patients with MAC enrolled in the MITRAL (Mitral Implantation of TRAnscathether vaLves) II trial (NCT04408430) across 13 centers undergoing transcatheter mitral valve replacement screening. Core laboratories assessed MAC severity using 3D-TEE and CT. Correlation and agreement were assessed via Spearman and intraclass correlation coefficients. Hemodynamic parameters of mitral stenosis (MS) and regurgitation were obtained from two-dimensional transthoracic echocardiography (2D-TTE) and 3D-TEE. Linear regression evaluated associations with MAC scores. Results
The analysis included 164 patients (75% females, mean age 75.5 ± 9.1 years). The mean MAC scores were 8.0 ± 0.44 by CT and 8.2 ± 0.45 by 3D-TEE. A modest positive correlation (Spearman correlation coefficient = 0.34; P Conclusions
3D-TEE provides complementary and functionally relevant MAC assessment, correlating with MS severity. It may serve as a useful adjunct to CT in transcatheter mitral valve replacement evaluation, especially when contrast imaging is limited.