Abstract

Background Oxygenation-sensitive (OS) cardiovascular magnetic resonance (CMR), using breathing maneuver-induced stress and blood oxygen level-dependent contrast, is a well-tolerated, non-invasive approach for assessing myocardial oxygenation. This study evaluated two real-time CMR sequences and a semi-automated analysis workflow to enable continuous, motion-robust assessment of myocardial oxygenation dynamics, aiming to overcome limitations of electrocardiogram (ECG)-triggered acquisitions and reduce manual evaluation requirements. Methods Signal intensity dynamics of ten young healthy female volunteers were analyzed from images acquired on a 3T scanner using an ECG-triggered balanced steady-state free precession (bSSFP) sequence, a real-time (RT) bSSFP sequence, and a RT fast low-angle short (FLASH) sequence. Images were obtained in a mid-ventricular slice while participants performed a breathing maneuver consisting of normal breathing, paced hyperventilation, and a prolonged breath hold. A semi-automated processing pipeline was implemented to generate motion-resolved oxygenation maps using retrospective cardiac phase binning, deformable image registration, and automated segmentation. Results The RT sequences captured end-systolic global myocardial signal intensity change (ΔSI, relative to reference frames at breath-hold start) with dynamics comparable to those of the ECG-triggered bSSFP sequence. As expected in healthy volunteers, ΔSI decreased during hyperventilation and recovered during the prolonged breath-hold. At 20-30s, oxygenation responses at end-systole were 3.95%[3.36, 7.50] for ECG-triggered bSSFP, 5.47%[3.31, 9.08] for RT bSSFP, and 3.24%[1.99, 4.80] for RT FLASH. RT FLASH showed fewer artifacts but lower contrast and smaller ΔSI than the bSSFP sequences, with inter-sequence differences appearing modest in mixed-effects analysis. Conclusions This exploratory study demonstrates the feasibility of combining real-time MR sequences with a semi-automated processing pipeline for continuous assessment of T2∕T2*-related myocardial oxygenation dynamics. Potential confounders, including through-plane motion and physiological drift, warrant further investigation.

DOI: 10.1016/j.jocmr.2026.102751 · PubMed: 42242607

Cite this article

Vogt N, Lebza S, Felblinger J, Bosser G, Odille F. Monitoring myocardial oxygenation response to respiratory maneuvers using real-time magnetic resonance imaging. J Cardiovasc Magn Reson. 2026. doi:10.1016/j.jocmr.2026.102751

RIS (EndNote, Zotero, Mendeley)BibTeX

Spotted a mistake? Suggest a correction

Top studies every Monday

The week’s key trials and guidelines in your specialties, plus any topics you follow. By email, free.

Get the weekly digest

More in Radiology & Imaging

Research · eBioMedicine · Nov 24, 2026 · Neurology, Radiology & Imaging

Brain and spinal cord inflammation are linked and brain lesions predict spinal cord thinning

Research · Insights Imaging · Nov 20, 2026 · Radiology & Imaging

Integrated system predicts disease-free survival in pancreatic cancer patients better

Meta-analysis · Eur Radiol Exp · Nov 20, 2026 · Radiology & Imaging, Oncology

No pancreatic tumor MRI radiomics studies reported all necessary imaging parameters for reproducibility

Research · Arthritis Res Ther · Nov 20, 2026 · Rheumatology, Radiology & Imaging

Siglec-9 PET/CT imaging was associated with higher tracer uptake in patients with polymyalgia rheumatica

Research · Insights Imaging · Nov 19, 2026 · Radiology & Imaging

Dual-phase photon-counting detector localized parathyroid adenomas with 67.3% to 83.7% sensitivity